New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
APAC S023OVR3SA / S023IVR3SA-TR Heat Pump
APAC S023OVR3SA / S023IVR3SA-TR is a 22.4 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7456).
- Energy rating (cooling)
- 1.5
- Heating: 1
- Annual electricity use
- 11,916 kWh
- 1,904 cooling + 10,012 heating
- Estimated running cost
- $3,932 / year
- $328 / month Β· $39,323 over 10 years
- Capacity
- 22.4 kW cooling
- 22.7 kW heating
8% more electricity than the median of 37 comparable 20 kW reverse cycle ducted split system registrations (11,029 kWh a year) in the cold zone. Uses less than 16% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 11% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
APAC S023OVR3SA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 11,916 | $3,932 | $39,323 |
| Mixed zone | 6,827 | $2,253 | $22,529 |
| Hot zone | 8,990 | $2,967 | $29,667 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 22.4 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAS200DY1 / FDYA200AV122.4 kW heating20 kW cooling9,309 kWh/yr | 2.5 | $3,072 | |
| Haier 1U200S5SA2FB / AD200S5SH2FA22.4 kW heating20 kW cooling9,384 kWh/yr | 2.5 | $3,097 | |
| Mitsubishi Heavy Industries FDCA200VSA-W/FDUA200VH22.4 kW heating20 kW cooling9,482 kWh/yr | 3 | $3,129 | |
| Panasonic U-200PZH3R8 / S-200PE4R22.4 kW heating20 kW cooling9,498 kWh/yr | 3 | $3,134 | |
| Actron Air CRS20AT / ECA20AS & EFA20AS22 kW heating19.8 kW cooling9,691 kWh/yr | 2.5 | $3,198 |
Heat pumps similar to the APAC S023OVR3SA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-224PZH3R8 / S-224PE4R25 kW heating22.4 kW cooling10,967 kWh/yr | 2.5 | $3,619 | |
| Panasonic U-224PE2R8A/S-224PE3R5B25 kW heating22.4 kW cooling13,247 kWh/yr | 2 | $4,372 | |
| Fujitsu AOTH90KRTA/ARTH90KHTA25 kW heating22.4 kW cooling12,261 kWh/yr | 2 | $4,046 | |
| Temperzone ISD 251LYX / OSA 251RLTFH23.3 kW heating22.5 kW cooling13,011 kWh/yr | 1 | $4,294 | |
| Actron Air CRS23AT / EVA23AS24.5 kW heating22.6 kW cooling10,570 kWh/yr | 2.5 | $3,488 | |
| Actron Air CRS23AT / ECA23AS & EFA23AS24.5 kW heating22.6 kW cooling10,570 kWh/yr | 2.5 | $3,488 | |
| Midea MOUU-220HD1N1-R/MHU-220HAN124.5 kW heating22 kW cooling12,222 kWh/yr | 2 | $4,033 | |
| Haier 1U250S5SA2FB / AD250S5SH2FA25 kW heating22 kW cooling11,034 kWh/yr | 2.5 | $3,641 |
Compare S023OVR3SA / S023IVR3SA-TR with another model
APAC S023OVR3SA specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 22.40 kW
- Cooling power input
- 6.73 kW
- Rated heating capacity (7 Β°C)
- 22.73 kW
- Heating power input
- 6.00 kW
- EER, full load (tested)
- 3.15
- COP, full load (tested)
- 3.63
- Rated AEER
- 3.28
- Rated ACOP
- 3.73
- Standby power (PIA)
- 28.5 W
- Compressor
- Fixed speed
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Australia, Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
APAC S023OVR3SA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 4,261 | 3,375 |
| Coldresidential | residential | 1.5 | 1.0 | 1,904 | 10,012 |
| Mixedcommercial | commercial | β | β | 5,274 | 1,832 |
| Mixedresidential | residential | 1.5 | 1.5 | 2,867 | 3,960 |
| Hotcommercial | commercial | β | β | 11,375 | 426 |
| Hotresidential | residential | 1.5 | 1.5 | 8,325 | 665 |
Part-load test points (6 values)
- h__h2_full_cap_power_rated
- 5560 W
- h__h3_have_full_cap_results
- No
- h__h2_full_cap_heat_cap_rated
- 18700 W
- c__low_temp_full_cap_power_rated
- 6040 W
- c__low_temp_have_full_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 23960 W
Other model numbers on registration AAC7456
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC7456
- GEMS registration id
- 153282
- Status
- approved, available (self-reported)
- Registration expires
- 1 May 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- S023OVR3SA / S023ILR1SA-
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.