New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Panasonic U-224PE2R8A/S-224PE3R5B Heat Pump
Panasonic U-224PE2R8A/S-224PE3R5B is a 22.4 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8059).
- Energy rating (cooling)
- 2
- Heating: 1
- Annual electricity use
- 13,247 kWh
- 1,676 cooling + 11,571 heating
- Estimated running cost
- $4,372 / year
- $364 / month Β· $43,715 over 10 years
- Capacity
- 22.4 kW cooling
- 25 kW heating
20% more electricity than the median of 37 comparable 20 kW reverse cycle ducted split system registrations (11,029 kWh a year) in the cold zone. Uses less than 3% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 10% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Panasonic U-224PE2R8A running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 13,247 | $4,372 | $43,715 |
| Mixed zone | 6,974 | $2,301 | $23,014 |
| Hot zone | 8,259 | $2,725 | $27,255 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 22.4 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAS200DY1 / FDYA200AV122.4 kW heating20 kW cooling9,309 kWh/yr | 2.5 | $3,072 | |
| Haier 1U200S5SA2FB / AD200S5SH2FA22.4 kW heating20 kW cooling9,384 kWh/yr | 2.5 | $3,097 | |
| Mitsubishi Heavy Industries FDCA200VSA-W/FDUA200VH22.4 kW heating20 kW cooling9,482 kWh/yr | 3 | $3,129 | |
| Panasonic U-200PZH3R8 / S-200PE4R22.4 kW heating20 kW cooling9,498 kWh/yr | 3 | $3,134 | |
| Actron Air CRS20AT / EVA20AS22 kW heating19.8 kW cooling9,691 kWh/yr | 2.5 | $3,198 |
Heat pumps similar to the Panasonic U-224PE2R8A
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Fujitsu AOTH90KRTA/ARTH90KHTA25 kW heating22.4 kW cooling12,261 kWh/yr | 2 | $4,046 | |
| APAC S023OVR3SA / S023ILR1SA-22.7 kW heating22.4 kW cooling11,916 kWh/yr | 1.5 | $3,932 | |
| APAC S023OVR3SA / S023IVR3SA-TR22.7 kW heating22.4 kW cooling11,916 kWh/yr | 1.5 | $3,932 | |
| Temperzone ISD 251LYX / OSA 251RLTFH23.3 kW heating22.5 kW cooling13,011 kWh/yr | 1 | $4,294 | |
| Actron Air CRS23AT / EVA23AS24.5 kW heating22.6 kW cooling10,570 kWh/yr | 2.5 | $3,488 | |
| Actron Air CRS23AT / ECA23AS & EFA23AS24.5 kW heating22.6 kW cooling10,570 kWh/yr | 2.5 | $3,488 | |
| Haier 1U250S5SA2FB / AD250S5SH2FA25 kW heating22 kW cooling11,034 kWh/yr | 2.5 | $3,641 | |
| Midea UCMI220OC-3PH/DUCMI220IHC-3PH24.5 kW heating22 kW cooling12,222 kWh/yr | 2 | $4,033 |
Compare U-224PE2R8A/S-224PE3R5B with another model
Panasonic U-224PE2R8A specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 22.40 kW
- Cooling power input
- 7.46 kW
- Rated heating capacity (7 Β°C)
- 25.00 kW
- Heating power input
- 7.10 kW
- EER, full load (tested)
- 3.05
- COP, full load (tested)
- 3.40
- Rated AEER
- 2.97
- Rated ACOP
- 3.48
- Standby power (PIA)
- 25.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 1456 Γ 486 Γ 916 mm
- Country of manufacture
- Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-224PE2R8A zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 3,708 | 3,804 |
| Coldresidential | residential | 2.0 | 1.0 | 1,676 | 11,571 |
| Mixedcommercial | commercial | β | β | 4,645 | 2,018 |
| Mixedresidential | residential | 2.0 | 1.5 | 2,604 | 4,370 |
| Hotcommercial | commercial | β | β | 10,197 | 451 |
| Hotresidential | residential | 2.0 | 1.5 | 7,562 | 697 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 9300 W
- c__t1_half_cap_power_rated
- 3190 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 3500 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 21000 W
- h__h1_half_cap_heat_cap_rated
- 12500 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 6818.4400000000005 W
- c__low_temp_half_cap_power_rated
- 2915.6600000000003 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 12000 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 24124.8 W
- c__low_temp_half_cap_cooling_cap_rated
- 12924 W
New Zealand E3 registration details
- Registration number
- AAC8059
- GEMS registration id
- 159445
- Status
- approved, available (self-reported)
- Registration expires
- 14 February 2029
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.