New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
APAC S095OVR3SA- / S095IHR3SA--TR Heat Pump
APAC S095OVR3SA- / S095IHR3SA--TR is a 94.1 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7355).
- Energy rating (cooling)
- 1
- Heating: 0
- Annual electricity use
- 8,763 kWh
- Estimated running cost
- $2,892 / year
- $241 / month Β· $28,918 over 10 years
- Capacity
- 94.1 kW cooling
- 92.2 kW heating
39% less electricity than the median of 14 comparable 80 kW and above reverse cycle ducted split system registrations (14,339 kWh a year) in the cold zone. Uses less than 64% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 16% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
APAC S095OVR3SA- running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 8,763 | $2,892 | $28,918 |
| Mixed zone | 13,101 | $4,323 | $43,233 |
| Hot zone | 37,570 | $12,398 | $123,981 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 94.1 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC S085OVR3SA- / S085IHR3SA--80.8 kW heating84.1 kW cooling7,214 kWh/yr | 1.5 | $2,381 | |
| APAC S085OVR3SA/S085IHR3SA-TR80.8 kW heating84.1 kW cooling7,214 kWh/yr | 1.5 | $2,381 | |
| Temperzone OSA950RKTBGV/ISD950KBXH-P90.4 kW heating88.7 kW cooling8,257 kWh/yr | 1 | $2,725 |
Heat pumps similar to the APAC S095OVR3SA-
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air CRV96AT / EVA96AT97 kW heating96 kW cooling54,965 kWh/yr | 2.5 | $18,138 | |
| Actron Air CRV960T / EVA960T97 kW heating96 kW cooling69,163 kWh/yr | 2.5 | $22,824 | |
| Temperzone OSA950RKTBGV/ISD950KBXH-P90.4 kW heating88.7 kW cooling8,257 kWh/yr | 1 | $2,725 |
Other APAC models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| APAC S085OVR3SA- / S085IHR3SA--XR80.8 kW heating84.1 kW cooling7,214 kWh/yr | 1.5 | $2,381 | |
| APAC S085OVR3SA- / S085IHR3SA--80.8 kW heating84.1 kW cooling7,214 kWh/yr | 1.5 | $2,381 |
Compare S095OVR3SA- / S095IHR3SA--TR with another model
APAC S095OVR3SA- specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 94.10 kW
- Cooling power input
- 29.80 kW
- Rated heating capacity (7 Β°C)
- 92.20 kW
- Heating power input
- 25.90 kW
- EER, full load (tested)
- 3.03
- COP, full load (tested)
- 3.42
- Rated AEER
- 3.09
- Rated ACOP
- 3.47
- Standby power (PIA)
- 200.0 W
- Compressor
- Variable speed
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- Australia, Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
APAC S095OVR3SA- zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 19,573 | β |
| Coldresidential | residential | 1.0 | 0.0 | 8,763 | β |
| Mixedcommercial | commercial | β | β | 24,034 | β |
| Mixedresidential | residential | 1.0 | 0.0 | 13,101 | β |
| Hotcommercial | commercial | β | β | 51,411 | β |
| Hotresidential | residential | 1.5 | 0.0 | 37,570 | β |
Part-load test points (1 values)
- c__low_temp_have_full_cap_results
- No
Other model numbers on registration AAC7355
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC7355
- GEMS registration id
- 153049
- Status
- approved, available (self-reported)
- Registration expires
- 14 March 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- S095OVR3SA- / S095IHR3SA -
- Regulatory standard
- [SEER Non Multi-Split >65kW] GEMS (Air Conditioners above 65kW) Determination 2022
- Test standard
- Simulation
- MEPS
- 2020
- Product class
- Class 25
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.