c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
6,435 kWh
724 cooling + 5,711 heating
Estimated running cost
$2,124 / year
$177 / month Β· $21,236 over 10 years
Capacity
12.5 kW cooling
13.5 kW heating

8% more electricity than the median of 81 comparable 12.5 kW reverse cycle split system registrations (5,949 kWh a year) in the cold zone. Uses less than 16% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 28% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Braemar KCHV125D1B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,435$2,124$21,236
Mixed zone 3,164$1,044$10,441
Hot zone 3,689$1,217$12,174

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657

Heat pumps similar to the Braemar KCHV125D1B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Daikin RZAV125FY1 / FCA125CVMA15 kW heating12.5 kW cooling5,137 kWh/yr4$1,695
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657
Hitachi PAS-5.0UFASMQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling5,594 kWh/yr3$1,846
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Hitachi PAS-5.0UFASNQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling5,602 kWh/yr3.5$1,849
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528

Compare KCHV125D1B/KBHV125D1S with another model

Braemar KCHV125D1B specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
12.50 kW
Cooling power input
3.85 kW
Rated heating capacity (7 Β°C)
13.50 kW
Heating power input
4.20 kW
EER, full load (tested)
3.36
COP, full load (tested)
3.25
Rated AEER
3.23
Rated ACOP
3.20
Standby power (PIA)
4.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
65.7 dB(A)
Outdoor sound power
69.1 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar KCHV125D1B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,3591,647
Coldresidential3.01.57245,711
Mixedcommercial––1,799811
Mixedresidential3.02.01,1382,026
Hotcommercial––4,518154
Hotresidential3.03.03,440249
Part-load test points (23 values)
c__t1_min_cap_power_rated
630 W
h__h1_min_cap_power_rated
730 W
c__t1_half_cap_power_rated
1350 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1380 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
3950 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3800 W
h__h1_half_cap_heat_cap_rated
6500 W
h__h2_full_cap_heat_cap_rated
9880 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
500 W
c__t1_min_cap_cooling_cap_rated
3250 W
c__low_temp_full_cap_power_rated
3518.9 W
c__low_temp_half_cap_power_rated
1233.9 W
c__t1_half_cap_cooling_cap_rated
6150 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
3400 W
c__low_temp_full_cap_cooling_cap_rated
13462.5 W
c__low_temp_half_cap_cooling_cap_rated
6623.55 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
KCHV125D1B/KBHV125D1SAAC646636,173

New Zealand E3 registration details

Registration number
AAC7003
GEMS registration id
149452
Status
approved, available (self-reported)
Registration expires
14 September 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gree.com. How the derived figures are calculated.