c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
7,336 kWh
805 cooling + 6,531 heating
Estimated running cost
$2,421 / year
$202 / month Β· $24,209 over 10 years
Capacity
13.2 kW cooling
17 kW heating

20% more electricity than the median of 146 comparable 12.5 kW reverse cycle ducted split system registrations (6,125 kWh a year) in the cold zone. Uses less than 10% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 23% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Braemar KCHV160D1B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,336$2,421$24,209
Mixed zone 3,628$1,197$11,972
Hot zone 4,078$1,346$13,457

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 13.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr4.5$1,440
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr3$1,471
Panasonic U-125PZ4R8 / S-125PE4RN12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Carrier 38QSM125D8S/42QSM125D8S13 kW heating12.3 kW cooling4,798 kWh/yr3.5$1,583

Heat pumps similar to the Braemar KCHV160D1B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air CRV13AS / EAA13AS & EFV13AS13.4 kW heating13.2 kW cooling10,211 kWh/yr2.5$3,370
Actron Air CRV13AS / EVV13AS13.4 kW heating13.2 kW cooling10,211 kWh/yr2.5$3,370
Panasonic U-140PZ4R5 / S-1014PF3E13.4 kW heating13.4 kW cooling5,530 kWh/yr2.5$1,825
Hisense AUW-125U4RH1/AUD-125UX4RSH115.5 kW heating13 kW cooling6,198 kWh/yr3$2,045
Haier 1U140S2SP5FA / AD140S2SM7FA15 kW heating13 kW cooling7,494 kWh/yr2$2,473
Fujitsu AOTH54KBTA/ARTH54KMTAP15 kW heating13 kW cooling7,120 kWh/yr2.5$2,350
Temperzone OSAT 130RLSFH / ISDT 130LY15.5 kW heating13 kW cooling6,450 kWh/yr2.5$2,129
Panasonic U-140PZ4R8 / S-1014PF3E13.4 kW heating13.4 kW cooling5,530 kWh/yr2.5$1,825

Compare KCHV160D1B/KGHV200A1S with another model

Braemar KCHV160D1B specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
13.20 kW
Cooling power input
3.90 kW
Rated heating capacity (7 Β°C)
17.00 kW
Heating power input
4.86 kW
EER, full load (tested)
3.40
COP, full load (tested)
3.46
Rated AEER
3.37
Rated ACOP
3.49
Standby power (PIA)
5.1 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Australia, China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar KCHV160D1B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,6051,982
Coldresidential3.01.58056,531
Mixedcommercial––2,105999
Mixedresidential2.52.01,2582,370
Hotcommercial––4,977200
Hotresidential3.03.03,757321
Part-load test points (23 values)
c__t1_min_cap_power_rated
780 W
h__h1_min_cap_power_rated
820 W
c__t1_half_cap_power_rated
1450 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1670 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
4170 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
4000 W
h__h1_half_cap_heat_cap_rated
7660 W
h__h2_full_cap_heat_cap_rated
13200 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
620 W
c__t1_min_cap_cooling_cap_rated
2900 W
c__low_temp_full_cap_power_rated
3564.6 W
c__low_temp_half_cap_power_rated
1325.3 W
c__t1_half_cap_cooling_cap_rated
6400 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
3000 W
c__low_temp_full_cap_cooling_cap_rated
14216.4 W
c__low_temp_half_cap_cooling_cap_rated
6892.799999999999 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
KCHV160D1B/KGHV200A1SAAC80222.57,678

New Zealand E3 registration details

Registration number
AAC8286
GEMS registration id
161997
Status
approved, available (self-reported)
Registration expires
4 June 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gree.com. How the derived figures are calculated.