New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Panasonic U-140PZ4R8 / S-1014PF3E Heat Pump
Panasonic U-140PZ4R8 / S-1014PF3E is a 13.4 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9365).
- Energy rating (cooling)
- 2.5
- Heating: 2
- Annual electricity use
- 5,530 kWh
- 823 cooling + 4,707 heating
- Estimated running cost
- $1,825 / year
- $152 / month Β· $18,249 over 10 years
- Capacity
- 13.4 kW cooling
- 13.4 kW heating
18% less electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 96% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 35% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Panasonic U-140PZ4R8 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 5,530 | $1,825 | $18,249 |
| Mixed zone | 3,008 | $993 | $9,926 |
| Hot zone | 3,970 | $1,310 | $13,101 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 13.4 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr | 4.5 | $1,440 | |
| Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr | 3 | $1,471 | |
| Panasonic U-125PZ4R5 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr | 3 | $1,565 | |
| Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr | 4 | $1,576 | |
| Carrier 38QSM125D8S/42QSM125D8S13 kW heating12.3 kW cooling4,798 kWh/yr | 3.5 | $1,583 |
Heat pumps similar to the Panasonic U-140PZ4R8
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Bonaire CRC6960014/CRC696011416 kW heating13.5 kW cooling7,954 kWh/yr | 2.5 | $2,625 | |
| Braemar KCHV160D1B/KGHV200A1S17 kW heating13.2 kW cooling7,336 kWh/yr | 3 | $2,421 | |
| Braemar KCHV160D1B/KGHV200A1T17 kW heating13.2 kW cooling7,336 kWh/yr | 3 | $2,421 | |
| Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling5,308 kWh/yr | 5 | $1,752 | |
| Actron Air CRV13AS / EVV13AS13.4 kW heating13.2 kW cooling10,211 kWh/yr | 2.5 | $3,370 | |
| Carrier 38QSH140D8S-1/42QSH140D8S-114.3 kW heating13.6 kW cooling5,575 kWh/yr | 4 | $1,840 | |
| Actron Air CRV13AS / EAA13AS & EFV13AS13.4 kW heating13.2 kW cooling10,211 kWh/yr | 2.5 | $3,370 | |
| Carrier 38QSM140D8S/42QSM140D8S14.5 kW heating13.6 kW cooling5,575 kWh/yr | 3.5 | $1,840 |
Compare U-140PZ4R8 / S-1014PF3E with another model
Panasonic U-140PZ4R8 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 13.40 kW
- Cooling power input
- 4.00 kW
- Rated heating capacity (7 Β°C)
- 13.40 kW
- Heating power input
- 3.56 kW
- EER, full load (tested)
- 3.38
- COP, full load (tested)
- 3.67
- Rated AEER
- 3.30
- Rated ACOP
- 3.70
- Standby power (PIA)
- 19.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Malaysia, China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-140PZ4R8 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,543 | 1,434 |
| Coldresidential | residential | 2.5 | 2.0 | 823 | 4,707 |
| Mixedcommercial | commercial | β | β | 2,019 | 734 |
| Mixedresidential | residential | 2.5 | 2.5 | 1,275 | 1,733 |
| Hotcommercial | commercial | β | β | 4,841 | 171 |
| Hotresidential | residential | 3.0 | 3.5 | 3,707 | 263 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 680 W
- h__h1_min_cap_power_rated
- 620 W
- h__h2_ext_cap_power_rated
- 4200 W
- c__t1_half_cap_power_rated
- 1500 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1350 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3500 W
- h__h2_ext_cap_heat_cap_rated
- 12000 W
- h__h1_half_cap_heat_cap_rated
- 6700 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 550 W
- c__t1_min_cap_cooling_cap_rated
- 3200 W
- c__low_temp_half_cap_power_rated
- 1320 W
- c__t1_half_cap_cooling_cap_rated
- 6700 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3350 W
- c__low_temp_half_cap_cooling_cap_rated
- 7150 W
New Zealand E3 registration details
- Registration number
- AAC9365
- GEMS registration id
- 172003
- Status
- approved, available (self-reported)
- Registration expires
- 1 September 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.