c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
5,575 kWh
648 cooling + 4,927 heating
Estimated running cost
$1,840 / year
$153 / month Β· $18,398 over 10 years
Capacity
13.6 kW cooling
14.3 kW heating

18% less electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 94% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 35% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Carrier 38QSH140D8S-1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,575$1,840$18,398
Mixed zone 2,888$953$9,530
Hot zone 3,253$1,073$10,735

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 13.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr4.5$1,440
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr3$1,471
Panasonic U-125PZ4R5 / S-125PE4R12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Carrier 38QSM125D8S/42QSM125D8S13 kW heating12.3 kW cooling4,798 kWh/yr3.5$1,583

Heat pumps similar to the Carrier 38QSH140D8S-1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling5,308 kWh/yr5$1,752
Bonaire CRC6960014/CRC696011416 kW heating13.5 kW cooling7,954 kWh/yr2.5$2,625
LG UU140WR3 U30/UMN140M3 N3015.5 kW heating13.8 kW cooling7,698 kWh/yr2.5$2,540
Panasonic U-140PZ4R5 / S-1014PF3E13.4 kW heating13.4 kW cooling5,530 kWh/yr2.5$1,825
Panasonic U-140PZ4R8 / S-1014PF3E13.4 kW heating13.4 kW cooling5,530 kWh/yr2.5$1,825
LG UU140WR2 U30/UMN140M3 N3015.5 kW heating13.8 kW cooling9,053 kWh/yr1.5$2,987
Kaden KDI48 / KDI4814 kW heating14 kW cooling5,394 kWh/yr4$1,780

Other Carrier models of similar capacity

ModelStarsEst. cost / yrCompare
Carrier 38QSM140D8S/42QSM140D8S14.5 kW heating13.6 kW cooling5,575 kWh/yr3.5$1,840

Compare 38QSH140D8S-1/42QSH140D8S-1 with another model

Carrier 38QSH140D8S-1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
13.60 kW
Cooling power input
4.15 kW
Rated heating capacity (7 Β°C)
14.30 kW
Heating power input
3.71 kW
EER, full load (tested)
3.32
COP, full load (tested)
3.87
Rated AEER
3.26
Rated ACOP
3.83
Standby power (PIA)
8.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38QSH140D8S-1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6251,532
Coldresidential4.02.06484,927
Mixedcommercial––1,197794
Mixedresidential3.52.51,0441,844
Hotcommercial––3,261168
Hotresidential4.03.02,988265
Part-load test points (25 values)
c__t1_min_cap_power_rated
893 W
h__h1_min_cap_power_rated
562 W
h__h2_ext_cap_power_rated
5061 W
c__t1_half_cap_power_rated
1733 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1299 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2800 W
h__h2_ext_cap_heat_cap_rated
14136 W
h__h1_half_cap_heat_cap_rated
6490 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
531 W
c__t1_min_cap_cooling_cap_rated
3211 W
c__low_temp_full_cap_power_rated
3793.1000000000004 W
c__low_temp_half_cap_power_rated
1100 W
c__t1_half_cap_cooling_cap_rated
6551 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3769 W
c__low_temp_full_cap_cooling_cap_rated
14647.199999999999 W
c__low_temp_half_cap_cooling_cap_rated
7320 W

New Zealand E3 registration details

Registration number
AAC6761
GEMS registration id
147390
Status
approved, available (self-reported)
Registration expires
31 May 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11