c/kWh
Energy rating (cooling)
4
Heating: 1.5
Annual electricity use
4,554 kWh
448 cooling + 4,106 heating
Estimated running cost
$1,503 / year
$125 / month Β· $15,028 over 10 years
Capacity
9.1 kW cooling
10.1 kW heating

2% more electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 41% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 43% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Carrier 38QHB090N8-1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,554$1,503$15,028
Mixed zone 2,125$701$7,013
Hot zone 2,316$764$7,643

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 9.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Braemar TCHV80T1S/TSHV80T1S8.5 kW heating8.2 kW cooling3,401 kWh/yr3.5$1,122
TCL TAC-28CHSD/TPH11IT8.5 kW heating8.2 kW cooling3,401 kWh/yr3.5$1,122

Heat pumps similar to the Carrier 38QHB090N8-1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Westinghouse HSV307HWAE/HSV307HWAI10.4 kW heating9.1 kW cooling4,785 kWh/yr4.5$1,579
Westinghouse WSD91HWA-E/WSD91HWA-I10.4 kW heating9.1 kW cooling4,785 kWh/yr4.5$1,579
Rinnai HONRTX90/HINRTX909.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Panasonic U-100PZ3R8/S-100PK3R9 kW heating9 kW cooling3,534 kWh/yr2.5$1,166
Kogan KASSSAC90HA9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Panasonic U-100PZ3R5/S-100PK3R9 kW heating9 kW cooling3,534 kWh/yr2.5$1,166
Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling3,874 kWh/yr4$1,278
Kogan KASSSAC90HE9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210

Compare 38QHB090N8-1/42QHB090N8-1 with another model

Carrier 38QHB090N8-1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
9.10 kW
Cooling power input
2.59 kW
Rated heating capacity (7 Β°C)
10.10 kW
Heating power input
2.90 kW
EER, full load (tested)
3.53
COP, full load (tested)
3.51
Rated AEER
3.51
Rated ACOP
3.48
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
51 dB(A)
Outdoor sound power
64.4 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38QHB090N8-1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––7481,245
Coldresidential4.01.54484,106
Mixedcommercial––1,066582
Mixedresidential3.52.07171,408
Hotcommercial––2,683109
Hotresidential4.03.02,141175
Part-load test points (23 values)
c__t1_min_cap_power_rated
650 W
h__h1_min_cap_power_rated
570 W
h__h2_ext_cap_power_rated
2910 W
c__t1_half_cap_power_rated
970 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1020 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2910 W
h__h2_ext_cap_heat_cap_rated
7320 W
h__h1_half_cap_heat_cap_rated
5090 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
470 W
c__t1_min_cap_cooling_cap_rated
3130 W
c__low_temp_half_cap_power_rated
770 W
c__t1_half_cap_cooling_cap_rated
4540 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3300 W
c__low_temp_half_cap_cooling_cap_rated
4900 W

New Zealand E3 registration details

Registration number
AAC8823
GEMS registration id
169299
Status
approved, available (self-reported)
Registration expires
15 June 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com.cn. How the derived figures are calculated.