c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
6,365 kWh
734 cooling + 5,631 heating
Estimated running cost
$2,100 / year
$175 / month Β· $21,005 over 10 years
Capacity
14 kW cooling
16 kW heating

4% less electricity than the median of 27 comparable 14 kW reverse cycle registrations (6,665 kWh a year) in the cold zone. Uses less than 56% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 29% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Carrier 38VS005181HCSG running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,365$2,100$21,005
Mixed zone 3,190$1,053$10,527
Hot zone 3,539$1,168$11,679

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH45KBTA513.2 kW heating12.5 kW cooling4,625 kWh/yr4$1,526
Kaden KM4814 kW heating13.5 kW cooling4,925 kWh/yr4$1,625
Midea MULMI0513B14 kW heating13.5 kW cooling4,925 kWh/yr4$1,625
Fujitsu AOTG45LBLA613.5 kW heating12.5 kW cooling4,946 kWh/yr3.5$1,632
Spt AM140C-514.4 kW heating13.6 kW cooling5,016 kWh/yr4$1,655

Heat pumps similar to the Carrier 38VS005181HCSG

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin RXYMQ5B2VM14 kW heating14 kW cooling5,795 kWh/yr2.5$1,912
Fujitsu AJT045LCLCH14 kW heating14 kW cooling6,665 kWh/yr2.5$2,199
Hisense AVW-48HJFAH116 kW heating14 kW cooling6,528 kWh/yr3.5$2,154
Toshiba MCY-MHP0504HS-A16 kW heating14 kW cooling6,365 kWh/yr3$2,100
Daikin RXYMQ5BVM14 kW heating14 kW cooling5,792 kWh/yr2.5$1,911
Midea MDV-V140WHN8(At)14 kW heating14 kW cooling6,247 kWh/yr2$2,062
Midea MV8M-140WV2RN816 kW heating14 kW cooling6,767 kWh/yr2.5$2,233
Actron Air MMV-140CT16 kW heating14 kW cooling6,767 kWh/yr2.5$2,233

Compare 38VS005181HCSG with another model

Carrier 38VS005181HCSG specifications

Type
Reverse cycle
Configuration
–
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
–
EER, full load (tested)
3.89
COP, full load (tested)
4.49
Rated AEER
3.79
Rated ACOP
4.06
Standby power (PIA)
26.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
65 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China, Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier 38VS005181HCSG zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,5031,747
Coldresidential3.02.07345,631
Mixedcommercial––1,902896
Mixedresidential3.02.51,1482,042
Hotcommercial––4,237213
Hotresidential4.03.53,217322
Part-load test points (18 values)
c__t1_half_cap_power_rated
1125 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1395 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
4405 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_full_cap_heat_cap_rated
13000 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
3294.97 W
c__low_temp_half_cap_power_rated
1028.25 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
15078 W
c__low_temp_half_cap_cooling_cap_rated
7539 W

New Zealand E3 registration details

Registration number
AAC7756
GEMS registration id
–
Status
approved
Registration expires
2 September 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.