c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
5,016 kWh
650 cooling + 4,366 heating
Estimated running cost
$1,655 / year
$138 / month Β· $16,553 over 10 years
Capacity
13.6 kW cooling
14.4 kW heating

About the same electricity as the median of 5 comparable 14 kW reverse cycle fixed registrations (5,016 kWh a year) in the cold zone. Uses less than 40% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Spt AM140C-5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,016$1,655$16,553
Mixed zone 2,700$891$8,910
Hot zone 3,213$1,060$10,603

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 13.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH45KBTA513.2 kW heating12.5 kW cooling4,625 kWh/yr4$1,526
Bonaire H5M125S1AE12.2 kW heating12.2 kW cooling4,758 kWh/yr3.5$1,570
TECO TSOM123HVAG512.6 kW heating12.3 kW cooling4,771 kWh/yr3.5$1,574

Heat pumps similar to the Spt AM140C-5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air MRC-135DS-514 kW heating13.5 kW cooling5,548 kWh/yr3.5$1,831
Kaden KM4814 kW heating13.5 kW cooling4,925 kWh/yr4$1,625
Carrier 38QUM135D8S513.5 kW heating13.5 kW cooling5,402 kWh/yr3$1,783
Kaden KM13.014 kW heating13 kW cooling5,594 kWh/yr3$1,846
Midea MULMI0513B14 kW heating13.5 kW cooling4,925 kWh/yr4$1,625
Hisense AMW5-125U4RTAG14.2 kW heating12.6 kW cooling5,911 kWh/yr3$1,951
Emerald ACR126U14.5 kW heating12.6 kW cooling6,014 kWh/yr3$1,985
Fujitsu AOTH45KBTA513.2 kW heating12.5 kW cooling4,625 kWh/yr4$1,526

Compare AM140C-5 with another model

Spt AM140C-5 specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
13.60 kW
Cooling power input
3.70 kW
Rated heating capacity (7 Β°C)
14.40 kW
Heating power input
3.10 kW
EER, full load (tested)
3.47
COP, full load (tested)
4.28
Rated AEER
3.62
Rated ACOP
4.55
Standby power (PIA)
18.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
69.4 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Spt AM140C-5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,0841,386
Coldresidential4.02.56504,366
Mixedcommercial––1,506733
Mixedresidential3.53.01,0331,667
Hotcommercial––3,697174
Hotresidential4.03.52,947266
Part-load test points (25 values)
c__t1_min_cap_power_rated
800 W
h__h1_min_cap_power_rated
660 W
h__h2_ext_cap_power_rated
4900 W
c__t1_half_cap_power_rated
1300 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1270 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3800 W
h__h2_ext_cap_heat_cap_rated
15000 W
h__h1_half_cap_heat_cap_rated
6800 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
590 W
c__t1_min_cap_cooling_cap_rated
5100 W
c__low_temp_full_cap_power_rated
3381.8 W
c__low_temp_half_cap_power_rated
1020 W
c__t1_half_cap_cooling_cap_rated
7480 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
5000 W
c__low_temp_full_cap_cooling_cap_rated
14647.199999999999 W
c__low_temp_half_cap_cooling_cap_rated
7600 W

New Zealand E3 registration details

Registration number
AAC8196
GEMS registration id
161114
Status
approved, available (self-reported)
Registration expires
30 April 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.