c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
1,310 kWh
157 cooling + 1,153 heating
Estimated running cost
$432 / year
$36 / month Β· $4,323 over 10 years
Capacity
2.5 kW cooling
3 kW heating

22% more electricity than the median of 177 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 8% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 83% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin DRXF25T2VMA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,310$432$4,323
Mixed zone 663$219$2,188
Hot zone 756$249$2,495

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling725 kWh/yr6$239
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr7$261

Heat pumps similar to the Daikin DRXF25T2VMA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai HSNRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Midea MFAG26VB-W/MFAG26VB-N2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Pioneer International HPR-09A22.6 kW heating2.5 kW cooling845 kWh/yr4$279
Carrier 42QHG026N8PB/38QUH026N8PB2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Carrier 38QRF026N8/42QRF026N82.8 kW heating2.5 kW cooling897 kWh/yr5$296
Rinnai HONRTX25/HINRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Comfee CASG-XG26B/CASN-XG26B2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Kaden KSI-2.52.8 kW heating2.5 kW cooling897 kWh/yr5$296

Compare DRXF25T2VMA / DTXF25T2VMA with another model

Daikin DRXF25T2VMA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.50 kW
Cooling power input
0.67 kW
Rated heating capacity (7 Β°C)
3.00 kW
Heating power input
0.78 kW
EER, full load (tested)
3.83
COP, full load (tested)
4.14
Rated AEER
3.66
Rated ACOP
3.78
Standby power (PIA)
3.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
56 dB(A)
Outdoor sound power
59 dB(A)
Demand response (AS/NZS 4755)
Yes (requires additional part)
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin DRXF25T2VMA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––339377
Coldresidential2.51.51571,153
Mixedcommercial––423189
Mixedresidential2.52.0241422
Hotcommercial––92643
Hotresidential3.02.569066
Part-load test points (20 values)
h__h2_ext_cap_power_rated
740 W
c__t1_half_cap_power_rated
270 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
310 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
2300 W
h__h1_half_cap_heat_cap_rated
1500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
612.38 W
c__low_temp_half_cap_power_rated
246.78 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1250 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
2692.5 W
c__low_temp_half_cap_cooling_cap_rated
1346.25 W

New Zealand E3 registration details

Registration number
AAC6941
GEMS registration id
149110
Status
approved, available (self-reported)
Registration expires
5 September 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.