New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Daikin RXM46AVMZ/FTXM46AVMZ Heat Pump
Daikin RXM46AVMZ/FTXM46AVMZ is a 4.6 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration ZAC0857).
- Energy rating (cooling)
- 4
- Heating: 2
- Annual electricity use
- 2,112 kWh
- 227 cooling + 1,885 heating
- Estimated running cost
- $697 / year
- $58 / month Β· $6,970 over 10 years
- Capacity
- 4.6 kW cooling
- 5.4 kW heating
2% less electricity than the median of 228 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 61% of them.
Across all 3,566 air conditioner registrations sold in Australia, it uses less than 75% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Daikin RXM46AVMZ running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,112 | $697 | $6,970 |
| Mixed zone | 1,054 | $348 | $3,478 |
| Hot zone | 1,151 | $380 | $3,798 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 4.6 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr | 4.5 | $509 | |
| Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr | 4.5 | $518 | |
| Fujitsu AOTH14KNCA/ASTH14KNCA4.7 kW heating4.2 kW cooling1,822 kWh/yr | 4 | $601 | |
| Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr | 4 | $606 | |
| Solar Acdc DGWA1-ACDC-18KR25 kW heating5 kW cooling1,905 kWh/yr | 3.5 | $629 |
Heat pumps similar to the Daikin RXM46AVMZ
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Toshiba RAS-16E2AVRG-A / RAS-B16E2KVRG-A5.5 kW heating4.6 kW cooling2,922 kWh/yr | 3 | $964 | |
| Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr | 4 | $606 | |
| Mitsubishi Heavy Industries SRC45ZSPA-W / SRK45ZSPA-W5 kW heating4.5 kW cooling2,095 kWh/yr | 2.5 | $691 | |
| LG WS18TWU / WS18TWN5.9 kW heating4.8 kW cooling2,712 kWh/yr | 3.5 | $895 | |
| LG AS18S1U / AS18S1N5.2 kW heating4.8 kW cooling2,188 kWh/yr | 3.5 | $722 | |
| Midea MFAG51VA-W/MFCS50VA-N5.5 kW heating4.9 kW cooling2,122 kWh/yr | 4.5 | $700 |
Other Daikin models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr | 4.5 | $509 | |
| Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr | 4.5 | $518 |
Compare RXM46AVMZ/FTXM46AVMZ with another model
Daikin RXM46AVMZ specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 4.60 kW
- Cooling power input
- β
- Rated heating capacity (7 Β°C)
- 5.40 kW
- Heating power input
- β
- EER, full load (tested)
- 3.90
- COP, full load (tested)
- 3.71
- Rated AEER
- 4.02
- Rated ACOP
- 3.87
- Standby power (PIA)
- 1.4 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 60 dB(A)
- Outdoor sound power
- 59 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Daikin RXM46AVMZ zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 414 | 599 |
| Coldresidential | residential | 4.0 | 2.0 | 227 | 1,885 |
| Mixedcommercial | commercial | β | β | 564 | 310 |
| Mixedresidential | residential | 3.5 | 2.5 | 355 | 699 |
| Hotcommercial | commercial | β | β | 1,342 | 63 |
| Hotresidential | residential | 4.0 | 3.0 | 1,051 | 100 |
Part-load test points (21 values)
- c__t1_min_cap_power_rated
- 231 W
- h__h2_ext_cap_power_rated
- 1630 W
- c__t1_half_cap_power_rated
- 495 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 530 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 4900 W
- h__h1_half_cap_heat_cap_rated
- 2700 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 179 W
- c__t1_min_cap_cooling_cap_rated
- 1100 W
- c__low_temp_half_cap_power_rated
- 390 W
- c__t1_half_cap_cooling_cap_rated
- 2300 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 1150 W
- c__low_temp_half_cap_cooling_cap_rated
- 2450 W
New Zealand E3 registration details
- Registration number
- ZAC0857
- GEMS registration id
- β
- Status
- approved
- Registration expires
- n/a (NZ registration)
- Registered for sale in
- New Zealand
- Family
- β
- Regulatory standard
- Energy Efficiency (Energy Using Products) Amendment Regulations 2020 Schedule 2A
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.