c/kWh
Energy rating (cooling)
3.5
Heating: 1.5
Annual electricity use
2,712 kWh
248 cooling + 2,464 heating
Estimated running cost
$895 / year
$75 / month Β· $8,950 over 10 years
Capacity
4.8 kW cooling
5.9 kW heating

26% more electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 1% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 66% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

LG WS18TWU running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,712$895$8,950
Mixed zone 1,256$414$4,145
Hot zone 1,291$426$4,260

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 4.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the LG WS18TWU

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MFAG51VA-W/MFCS50VA-N5.5 kW heating4.9 kW cooling2,122 kWh/yr4.5$700
Comfee CASG-XG50/CASN-XG505.5 kW heating5 kW cooling2,168 kWh/yr4.5$715
Comfee CASG-XG51/CASN-XG515.5 kW heating5 kW cooling2,151 kWh/yr4.5$710
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNA1A/I4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509

Other LG models of similar capacity

ModelStarsEst. cost / yrCompare
LG AS18S1U / AS18S1N5.2 kW heating4.8 kW cooling2,188 kWh/yr3.5$722

Compare WS18TWU / WS18TWN with another model

LG WS18TWU specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
4.80 kW
Cooling power input
1.46 kW
Rated heating capacity (7 Β°C)
5.90 kW
Heating power input
1.68 kW
EER, full load (tested)
3.57
COP, full load (tested)
3.68
Rated AEER
3.27
Rated ACOP
3.51
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
63.2 dB(A)
Outdoor sound power
60.9 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

LG WS18TWU zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––425767
Coldresidential3.51.52482,464
Mixedcommercial––599365
Mixedresidential3.52.0400856
Hotcommercial––1,48072
Hotresidential3.53.01,176115
Part-load test points (23 values)
c__t1_min_cap_power_rated
380 W
h__h2_ext_cap_power_rated
1870 W
c__t1_half_cap_power_rated
490 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
597 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
4420 W
h__h1_half_cap_heat_cap_rated
2950 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
280 W
c__t1_min_cap_cooling_cap_rated
1750 W
c__low_temp_full_cap_power_rated
1334.44 W
c__low_temp_half_cap_power_rated
400 W
c__t1_half_cap_cooling_cap_rated
2400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1850 W
c__low_temp_full_cap_cooling_cap_rated
5169.599999999999 W
c__low_temp_half_cap_cooling_cap_rated
2585 W

New Zealand E3 registration details

Registration number
AAC8354
GEMS registration id
163380
Status
approved, available (self-reported)
Registration expires
17 July 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.