c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
2,188 kWh
248 cooling + 1,940 heating
Estimated running cost
$722 / year
$60 / month Β· $7,220 over 10 years
Capacity
4.8 kW cooling
5.2 kW heating

2% more electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 42% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 73% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

LG AS18S1U running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,188$722$7,220
Mixed zone 1,080$356$3,564
Hot zone 1,281$423$4,227

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 4.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNA1A/I4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the LG AS18S1U

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MFAG51VA-W/MFCS50VA-N5.5 kW heating4.9 kW cooling2,122 kWh/yr4.5$700
Comfee CASG-XG50/CASN-XG505.5 kW heating5 kW cooling2,168 kWh/yr4.5$715
Comfee CASG-XG51/CASN-XG515.5 kW heating5 kW cooling2,151 kWh/yr4.5$710
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNA1A/I4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606

Other LG models of similar capacity

ModelStarsEst. cost / yrCompare
LG WS18TWU / WS18TWN5.9 kW heating4.8 kW cooling2,712 kWh/yr3.5$895

Compare AS18S1U / AS18S1N with another model

LG AS18S1U specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
4.80 kW
Cooling power input
1.49 kW
Rated heating capacity (7 Β°C)
5.20 kW
Heating power input
1.37 kW
EER, full load (tested)
3.48
COP, full load (tested)
3.91
Rated AEER
3.23
Rated ACOP
3.79
Standby power (PIA)
0.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
62 dB(A)
Outdoor sound power
61 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
837 Γ— 308 Γ— 189 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

LG AS18S1U zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––328597
Coldresidential3.52.02481,940
Mixedcommercial––526298
Mixedresidential3.52.5396684
Hotcommercial––1,42858
Hotresidential3.53.01,18893
Part-load test points (21 values)
c__t1_min_cap_power_rated
260 W
h__h2_ext_cap_power_rated
1830 W
c__t1_half_cap_power_rated
600 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
500 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
4450 W
h__h1_half_cap_heat_cap_rated
2600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
170 W
c__t1_min_cap_cooling_cap_rated
1200 W
c__low_temp_half_cap_power_rated
450 W
c__t1_half_cap_cooling_cap_rated
2400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1245 W
c__low_temp_half_cap_cooling_cap_rated
2600 W

New Zealand E3 registration details

Registration number
AAC9440
GEMS registration id
172314
Status
approved, available (self-reported)
Registration expires
17 September 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.