New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Daikin RZAC71CAV1 / FBA71BVMA Heat Pump
Daikin RZAC71CAV1 / FBA71BVMA is a 7.1 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8428).
- Energy rating (cooling)
- 2
- Heating: 1.5
- Annual electricity use
- 3,593 kWh
- 505 cooling + 3,088 heating
- Estimated running cost
- $1,186 / year
- $99 / month Β· $11,857 over 10 years
- Capacity
- 7.1 kW cooling
- 8 kW heating
10% more electricity than the median of 80 comparable 7 kW reverse cycle ducted split system registrations (3,264 kWh a year) in the cold zone. Uses less than 10% of them.
Across all 3,566 air conditioner registrations sold in Australia, it uses less than 52% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Daikin RZAC71CAV1 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,593 | $1,186 | $11,857 |
| Mixed zone | 1,996 | $659 | $6,587 |
| Hot zone | 2,396 | $791 | $7,907 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Fujitsu AOTH24KCTA/ARTH24KMTAP8 kW heating7.1 kW cooling0 kWh/yr | β | $0 | |
| Fujitsu AOTH24KBTA/ARTH24KMTAP8 kW heating7.1 kW cooling0 kWh/yr | β | $0 | |
| Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling2,674 kWh/yr | 3 | $882 | |
| Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,720 kWh/yr | 3.5 | $898 | |
| Mdv C-UV-74N8-QC3W / CDV-74A6N8-QC3W7.5 kW heating7.4 kW cooling2,744 kWh/yr | 3.5 | $906 |
Heat pumps similar to the Daikin RZAC71CAV1
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hyundai HYDCTAC71TD7.5 kW heating7.1 kW cooling2,770 kWh/yr | 3.5 | $914 | |
| Gree GFH24ACXF-S6DNE3D/O / GFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,127 kWh/yr | 3 | $1,032 | |
| Panasonic U-71PZH3R5 / S-71PE4R8 kW heating7.1 kW cooling3,014 kWh/yr | 3 | $995 | |
| Fujitsu AOTH24KCTA/ARTH24KMTAP8 kW heating7.1 kW cooling0 kWh/yr | β | $0 | |
| Fujitsu AOTH24KBTA/ARTH24KMTAP8 kW heating7.1 kW cooling0 kWh/yr | β | $0 | |
| Panasonic U-71PZ4R5 / S-71PE4R7.1 kW heating7.1 kW cooling2,870 kWh/yr | 2.5 | $947 | |
| Hyundai HYDCTAC71TA7.5 kW heating7.1 kW cooling2,770 kWh/yr | 3.5 | $914 | |
| TCL TCD71D1HWH-DVO/TCD71D1HWH-DVI7.5 kW heating7.1 kW cooling2,770 kWh/yr | 3.5 | $914 |
Compare RZAC71CAV1 / FBA71BVMA with another model
Daikin RZAC71CAV1 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 7.10 kW
- Cooling power input
- β
- Rated heating capacity (7 Β°C)
- 8.00 kW
- Heating power input
- β
- EER, full load (tested)
- 3.39
- COP, full load (tested)
- 4.04
- Rated AEER
- 3.22
- Rated ACOP
- 3.40
- Standby power (PIA)
- 15.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Daikin RZAC71CAV1 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,072 | 1,025 |
| Coldresidential | residential | 2.0 | 1.5 | 505 | 3,088 |
| Mixedcommercial | commercial | β | β | 1,338 | 562 |
| Mixedresidential | residential | 2.0 | 2.0 | 774 | 1,222 |
| Hotcommercial | commercial | β | β | 2,924 | 138 |
| Hotresidential | residential | 2.5 | 2.0 | 2,187 | 209 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 2050 W
- c__t1_half_cap_power_rated
- 840 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 930 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 7100 W
- h__h1_half_cap_heat_cap_rated
- 4000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 1965.1 W
- c__low_temp_half_cap_power_rated
- 767.76 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 3550 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 7646.7 W
- c__low_temp_half_cap_cooling_cap_rated
- 3823.35 W
New Zealand E3 registration details
- Registration number
- AAC8428
- GEMS registration id
- β
- Status
- approved
- Registration expires
- 1 September 2029
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- 10
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.