c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
6,017 kWh
667 cooling + 5,350 heating
Estimated running cost
$1,986 / year
$165 / month Β· $19,856 over 10 years
Capacity
12.5 kW cooling
15 kW heating

1% more electricity than the median of 81 comparable 12.5 kW reverse cycle split system registrations (5,949 kWh a year) in the cold zone. Uses less than 36% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 31% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin RZAV125F2Y1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,017$1,986$19,856
Mixed zone 2,966$979$9,788
Hot zone 3,319$1,095$10,953

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657

Heat pumps similar to the Daikin RZAV125F2Y1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDCA125VSX-W / FDE125VH14 kW heating12.5 kW cooling5,469 kWh/yr2.5$1,805
Mitsubishi Heavy Industries FDC125VSX-W / FDE125VH14 kW heating12.5 kW cooling5,469 kWh/yr2.5$1,805
Hitachi PAS-5.0UFASMQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling5,594 kWh/yr3$1,846
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Hitachi PAS-5.0UFASNQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling5,602 kWh/yr3.5$1,849
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528

Compare RZAV125F2Y1 / FHA125BVMA with another model

Daikin RZAV125F2Y1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Under ceiling
Rated cooling capacity (35 Β°C)
12.50 kW
Cooling power input
3.65 kW
Rated heating capacity (7 Β°C)
15.00 kW
Heating power input
4.21 kW
EER, full load (tested)
3.38
COP, full load (tested)
3.61
Rated AEER
3.37
Rated ACOP
3.52
Standby power (PIA)
14.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
62 dB(A)
Outdoor sound power
69 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RZAV125F2Y1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,1581,602
Coldresidential3.52.06675,350
Mixedcommercial––1,576801
Mixedresidential3.02.51,0521,914
Hotcommercial––3,830174
Hotresidential3.53.53,048271
Part-load test points (25 values)
c__t1_min_cap_power_rated
512 W
h__h1_min_cap_power_rated
651 W
h__h2_ext_cap_power_rated
4055 W
c__t1_half_cap_power_rated
1300 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1418 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3700 W
h__h2_ext_cap_heat_cap_rated
12200 W
h__h1_half_cap_heat_cap_rated
7500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
412 W
c__t1_min_cap_cooling_cap_rated
3100 W
c__low_temp_full_cap_power_rated
3340.67 W
c__low_temp_half_cap_power_rated
984 W
c__t1_half_cap_cooling_cap_rated
6300 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3300 W
c__low_temp_full_cap_cooling_cap_rated
13462.5 W
c__low_temp_half_cap_cooling_cap_rated
6300 W

New Zealand E3 registration details

Registration number
AAC6508
GEMS registration id
144559
Status
approved, available (self-reported)
Registration expires
27 February 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.