c/kWh
Energy rating (cooling)
2.5
Heating: 3
Annual electricity use
2,004 kWh
277 cooling + 1,727 heating
Estimated running cost
$661 / year
$55 / month Β· $6,613 over 10 years
Capacity
5 kW cooling
6 kW heating

7% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 83% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 77% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin RZAV50C2V1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,004$661$6,613
Mixed zone 1,084$358$3,577
Hot zone 1,239$409$4,089

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the Daikin RZAV50C2V1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Toshiba RAV-GP561ATP-A1/RAV-GM561UTP-A5.6 kW heating5 kW cooling2,017 kWh/yr3.5$666
Toshiba RAV-GP561ATP-A/RAV-GM561UTP-A5.6 kW heating5 kW cooling1,963 kWh/yr4$648
Midea MFAB-60WC/MULMIO185.2 kW heating5 kW cooling2,061 kWh/yr4$680
Hitachi PAS-2.0UFASNQ1 / PCI-2.0UFA1NQ6 kW heating5 kW cooling2,117 kWh/yr4$699
Panasonic U-50PZ3R5/S-50PY3E5 kW heating5 kW cooling1,982 kWh/yr2.5$654
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling1,936 kWh/yr5$639
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling1,940 kWh/yr5.5$640
Pioneer International HPR-18A25.1 kW heating5 kW cooling1,968 kWh/yr4$649

Compare RZAV50C2V1 / FCTA50AVMA with another model

Daikin RZAV50C2V1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
5.00 kW
Cooling power input
1.11 kW
Rated heating capacity (7 Β°C)
6.00 kW
Heating power input
1.27 kW
EER, full load (tested)
4.57
COP, full load (tested)
5.02
Rated AEER
4.28
Rated ACOP
4.52
Standby power (PIA)
17.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RZAV50C2V1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––547568
Coldresidential2.53.02771,727
Mixedcommercial––679309
Mixedresidential3.03.5418666
Hotcommercial––1,45988
Hotresidential4.04.01,110129
Part-load test points (20 values)
h__h2_ext_cap_power_rated
1400 W
c__t1_half_cap_power_rated
400 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
470 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5500 W
h__h1_half_cap_heat_cap_rated
3000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
1014.5400000000001 W
c__low_temp_half_cap_power_rated
365.6 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
2500 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
5385 W
c__low_temp_half_cap_cooling_cap_rated
2692.5 W

New Zealand E3 registration details

Registration number
AAC7180
GEMS registration id
150447
Status
approved, available (self-reported)
Registration expires
23 November 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.