c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
8,986 kWh
873 cooling + 8,113 heating
Estimated running cost
$2,965 / year
$247 / month Β· $29,654 over 10 years
Capacity
20 kW cooling
26 kW heating

10% less electricity than the median of 31 comparable 20 kW reverse cycle registrations (9,948 kWh a year) in the cold zone. Uses less than 74% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 15% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Emerald Energy ACV200U running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 8,986$2,965$29,654
Mixed zone 4,342$1,433$14,329
Hot zone 4,234$1,397$13,972

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 20 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MDV-V200WHN1(AUV)20 kW heating19 kW cooling6,799 kWh/yr4.5$2,244
Daikin RSUYA7AYM22.4 kW heating20 kW cooling7,360 kWh/yr3$2,429
Emerald ACV180U20.4 kW heating18.1 kW cooling7,823 kWh/yr3.5$2,582
Panasonic U-8MF3R725 kW heating22.4 kW cooling8,140 kWh/yr4$2,686
Rinnai MON6H19B1TA21.5 kW heating19 kW cooling8,459 kWh/yr4$2,791

Heat pumps similar to the Emerald Energy ACV200U

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai DONSR20Z920 kW heating20 kW cooling9,791 kWh/yr2$3,231
Daikin RSUYA7AYM22.4 kW heating20 kW cooling7,360 kWh/yr3$2,429
Rinnai DONSR20Z3TA22 kW heating20 kW cooling11,751 kWh/yr2$3,878
Midea MDV-V200WHN1(AUV)20 kW heating19 kW cooling6,799 kWh/yr4.5$2,244
Emerald ACV180U20.4 kW heating18.1 kW cooling7,823 kWh/yr3.5$2,582
Panasonic U-8MF3R725 kW heating22.4 kW cooling8,140 kWh/yr4$2,686
Daikin RSUYA8AYM25 kW heating22.4 kW cooling8,492 kWh/yr3$2,802
Mitsubishi Heavy Industries FDC224KXZPE122.4 kW heating22.4 kW cooling8,641 kWh/yr2.5$2,852

Compare ACV200U with another model

Emerald Energy ACV200U specifications

Type
Reverse cycle
Configuration
–
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
20.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
26.00 kW
Heating power input
–
EER, full load (tested)
4.60
COP, full load (tested)
4.13
Rated AEER
4.65
Rated ACOP
4.27
Standby power (PIA)
31.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
70.3 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Emerald Energy ACV200U zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,6382,531
Coldresidential4.02.58738,113
Mixedcommercial––2,1491,308
Mixedresidential4.03.01,3592,983
Hotcommercial––4,827303
Hotresidential5.04.03,771463
Part-load test points (20 values)
h__h1_min_cap_power_rated
1210 W
h__h2_ext_cap_power_rated
7390 W
c__t1_half_cap_power_rated
1600 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
2260 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
7060 W
h__h2_ext_cap_heat_cap_rated
23700 W
h__h1_half_cap_heat_cap_rated
13000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
1350 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
10000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
11400 W

New Zealand E3 registration details

Registration number
AAC8519
GEMS registration id
–
Status
approved
Registration expires
13 November 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.