c/kWh
Energy rating (cooling)
2
Heating: 1
Annual electricity use
11,751 kWh
1,437 cooling + 10,314 heating
Estimated running cost
$3,878 / year
$323 / month Β· $38,778 over 10 years
Capacity
20 kW cooling
22 kW heating

18% more electricity than the median of 31 comparable 20 kW reverse cycle registrations (9,948 kWh a year) in the cold zone. Uses less than 19% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 11% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Rinnai DONSR20Z3TA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 11,751$3,878$38,778
Mixed zone 5,792$1,911$19,114
Hot zone 6,793$2,242$22,417

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 20 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MDV-V200WHN1(AUV)20 kW heating19 kW cooling6,799 kWh/yr4.5$2,244
Daikin RSUYA7AYM22.4 kW heating20 kW cooling7,360 kWh/yr3$2,429
Emerald ACV180U20.4 kW heating18.1 kW cooling7,823 kWh/yr3.5$2,582
Panasonic U-8MF3R725 kW heating22.4 kW cooling8,140 kWh/yr4$2,686
Rinnai MON6H19B1TA21.5 kW heating19 kW cooling8,459 kWh/yr4$2,791

Heat pumps similar to the Rinnai DONSR20Z3TA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Emerald Energy ACV200U26 kW heating20 kW cooling8,986 kWh/yr4$2,965
Daikin RSUYA7AYM22.4 kW heating20 kW cooling7,360 kWh/yr3$2,429
Midea MDV-V200WHN1(AUV)20 kW heating19 kW cooling6,799 kWh/yr4.5$2,244
Emerald ACV180U20.4 kW heating18.1 kW cooling7,823 kWh/yr3.5$2,582
Daikin RSUYA8AYM25 kW heating22.4 kW cooling8,492 kWh/yr3$2,802
Panasonic U-8MF3R725 kW heating22.4 kW cooling8,140 kWh/yr4$2,686

Other Rinnai models of similar capacity

ModelStarsEst. cost / yrCompare
Rinnai DONSR20Z920 kW heating20 kW cooling9,791 kWh/yr2$3,231
Rinnai MON6H19B1TA21.5 kW heating19 kW cooling8,459 kWh/yr4$2,791

Compare DONSR20Z3TA with another model

Rinnai DONSR20Z3TA specifications

Type
Reverse cycle
Configuration
–
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
20.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
22.00 kW
Heating power input
–
EER, full load (tested)
3.32
COP, full load (tested)
3.83
Rated AEER
3.27
Rated ACOP
3.85
Standby power (PIA)
35.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
77 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Rinnai DONSR20Z3TA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3,1232,933
Coldresidential2.01.01,43710,314
Mixedcommercial––3,8891,474
Mixedresidential2.01.52,2033,589
Hotcommercial––8,480322
Hotresidential2.53.06,304489
Part-load test points (16 values)
h__h2_ext_cap_power_rated
7000 W
c__t1_half_cap_power_rated
2500 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
2200 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
15500 W
h__h1_half_cap_heat_cap_rated
11000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
10000 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC9571
GEMS registration id
–
Status
approved
Registration expires
18 November 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.