c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
3,401 kWh
433 cooling + 2,968 heating
Estimated running cost
$1,122 / year
$94 / month Β· $11,223 over 10 years
Capacity
8.2 kW cooling
8.5 kW heating

6% less electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 82% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 55% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Ers Tech ERS-AC82F01 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,401$1,122$11,223
Mixed zone 1,758$580$5,801
Hot zone 2,158$712$7,121

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Spt AW073C-1 / AW073E8.1 kW heating7.3 kW cooling3,037 kWh/yr4$1,002
Westinghouse HSV247HWAE/HSV247HWAI8.3 kW heating7.3 kW cooling3,063 kWh/yr4$1,011
Westinghouse WSD73HWA-E/WSD73HWA-I8.3 kW heating7.3 kW cooling3,063 kWh/yr4$1,011
Kogan KASSSAC80HF8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Kogan KASSSAC80HB8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083

Heat pumps similar to the Ers Tech ERS-AC82F01

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar TCHV08T1S/TSHV08T1S8.4 kW heating8.2 kW cooling3,414 kWh/yr3.5$1,127
Bonaire STH082S1AE/STH082S1AI8.4 kW heating8.2 kW cooling3,414 kWh/yr3.5$1,127
TCL TAC-28CHSD/TPH11IT8.5 kW heating8.2 kW cooling3,401 kWh/yr3.5$1,122
Kogan KASHSAC80TA8.5 kW heating8.2 kW cooling3,401 kWh/yr3.5$1,122
Braemar TCHV80T1S/TSHV80T1S8.5 kW heating8.2 kW cooling3,401 kWh/yr3.5$1,122
Bonaire CRC6911082/CRC69111828.5 kW heating8.2 kW cooling3,401 kWh/yr3.5$1,122
Kogan KASHSAC80TB8.5 kW heating8.2 kW cooling3,401 kWh/yr3.5$1,122
TCL TAC-28CHSD/VFIH8.4 kW heating8.2 kW cooling3,414 kWh/yr3.5$1,127

Compare ERS-AC82F01 with another model

Ers Tech ERS-AC82F01 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
8.20 kW
Cooling power input
2.30 kW
Rated heating capacity (7 Β°C)
8.50 kW
Heating power input
2.30 kW
EER, full load (tested)
3.53
COP, full load (tested)
3.75
Rated AEER
3.54
Rated ACOP
3.67
Standby power (PIA)
5.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
52 dB(A)
Outdoor sound power
64.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Ers Tech ERS-AC82F01 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––838917
Coldresidential3.52.04332,968
Mixedcommercial––1,117465
Mixedresidential3.02.56881,070
Hotcommercial––2,58698
Hotresidential3.53.52,005153
Part-load test points (18 values)
c__t1_half_cap_power_rated
810 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
750 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
3000 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
4200 W
h__h2_full_cap_heat_cap_rated
7900 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
2102.2000000000003 W
c__low_temp_half_cap_power_rated
650 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
4200 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
8831.4 W
c__low_temp_half_cap_cooling_cap_rated
4250 W

New Zealand E3 registration details

Registration number
AAC7894
GEMS registration id
157538
Status
approved, available (self-reported)
Registration expires
15 November 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.