c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
3,401 kWh
433 cooling + 2,968 heating
Estimated running cost
$1,122 / year
$94 / month Β· $11,223 over 10 years
Capacity
8.2 kW cooling
8.5 kW heating

6% less electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 82% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 55% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kogan KASHSAC80TA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,401$1,122$11,223
Mixed zone 1,758$580$5,801
Hot zone 2,158$712$7,121

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Spt AW073C-1 / AW073E8.1 kW heating7.3 kW cooling3,037 kWh/yr4$1,002
Westinghouse HSV247HWAE/HSV247HWAI8.3 kW heating7.3 kW cooling3,063 kWh/yr4$1,011
Westinghouse WSD73HWA-E/WSD73HWA-I8.3 kW heating7.3 kW cooling3,063 kWh/yr4$1,011
Kogan KASSSAC80HB8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Kogan KASSSAC80HF8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083

Heat pumps similar to the Kogan KASHSAC80TA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Aux ASW-H80A4/LER3DI9.1 kW heating8.2 kW cooling3,590 kWh/yr4.5$1,185
TCL TAC-28CHSD/TPH11IH8.4 kW heating8.2 kW cooling3,414 kWh/yr3.5$1,127
Bonaire CRC6911082/CRC69111828.5 kW heating8.2 kW cooling3,401 kWh/yr3.5$1,122
Ers Tech ERS-AC82F018.5 kW heating8.2 kW cooling3,401 kWh/yr3.5$1,122
TCL TAC-28CHSD/TPH11IT8.5 kW heating8.2 kW cooling3,401 kWh/yr3.5$1,122
Braemar TCHV80T1S/TSHV80T1S8.5 kW heating8.2 kW cooling3,401 kWh/yr3.5$1,122
Braemar TCHV08T1S/TSHV08T1S8.4 kW heating8.2 kW cooling3,414 kWh/yr3.5$1,127
Bonaire STH082S1AE/STH082S1AI8.4 kW heating8.2 kW cooling3,414 kWh/yr3.5$1,127

Compare KASHSAC80TA with another model

Kogan KASHSAC80TA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
8.20 kW
Cooling power input
2.30 kW
Rated heating capacity (7 Β°C)
8.50 kW
Heating power input
2.30 kW
EER, full load (tested)
3.53
COP, full load (tested)
3.75
Rated AEER
3.54
Rated ACOP
3.67
Standby power (PIA)
5.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
52 dB(A)
Outdoor sound power
64.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kogan KASHSAC80TA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––838917
Coldresidential3.52.04332,968
Mixedcommercial––1,117465
Mixedresidential3.02.56881,070
Hotcommercial––2,58698
Hotresidential3.53.52,005153
Part-load test points (18 values)
c__t1_half_cap_power_rated
810 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
750 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
3000 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
4200 W
h__h2_full_cap_heat_cap_rated
7900 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
2102.2000000000003 W
c__low_temp_half_cap_power_rated
650 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
4200 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
8831.4 W
c__low_temp_half_cap_cooling_cap_rated
4250 W

Other model numbers on registration AAC7077

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7077
GEMS registration id
150127
Status
approved, available (self-reported)
Registration expires
6 October 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
KASHSAC80T*
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.