New Zealand Β· costs in NZD
Reverse cycle split system air conditioner, wall hung
Euromatic EUR-9000FX Heat Pump
Euromatic EUR-9000FX is a 2.7 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7860).
- Energy rating (cooling)
- 2
- Heating: 1.5
- Annual electricity use
- 1,311 kWh
- 201 cooling + 1,110 heating
- Estimated running cost
- $433 / year
- $36 / month Β· $4,326 over 10 years
- Capacity
- 2.7 kW cooling
- 2.6 kW heating
22% more electricity than the median of 177 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 7% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 83% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Euromatic EUR-9000FX running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,311 | $433 | $4,326 |
| Mixed zone | 744 | $246 | $2,455 |
| Hot zone | 965 | $318 | $3,185 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 2.7 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr | 4 | $215 | |
| Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr | 6.5 | $256 | |
| Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr | 7 | $261 | |
| Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr | 7 | $261 | |
| Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr | 7 | $265 |
Heat pumps similar to the Euromatic EUR-9000FX
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Gree GWH09AGCXB-K6DNA1B/O / GWH09AGCXB-K6DNA1B/I2.9 kW heating2.7 kW cooling1,004 kWh/yr | 4.5 | $331 | |
| Kinghome KWH27ATBXB-K6DNA2/O / KWH27ATBXB-K6DNA2/I3 kW heating2.7 kW cooling1,276 kWh/yr | 3.5 | $421 | |
| Comfee CASG-XG25/CASN-XG252.8 kW heating2.7 kW cooling956 kWh/yr | 5.5 | $315 | |
| Braemar ACHV25D1S/ASHV25D1S3 kW heating2.7 kW cooling1,276 kWh/yr | 3.5 | $421 | |
| Tosot TWH09ATBXB-K6DNA1C/O / TWH09ATBXB-K6DNA3C/I3 kW heating2.7 kW cooling1,276 kWh/yr | 3.5 | $421 | |
| Gree GWH09AGCXB-K6DNA1B2.9 kW heating2.7 kW cooling1,004 kWh/yr | 4.5 | $331 | |
| Westinghouse WSD27HWC-E / WSD27HWC-I3.3 kW heating2.7 kW cooling1,015 kWh/yr | 6.5 | $335 | |
| Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr | 7 | $265 |
Compare EUR-9000FX with another model
Euromatic EUR-9000FX specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 2.69 kW
- Cooling power input
- 0.71 kW
- Rated heating capacity (7 Β°C)
- 2.60 kW
- Heating power input
- 0.68 kW
- EER, full load (tested)
- 3.79
- COP, full load (tested)
- 3.82
- Rated AEER
- 3.75
- Rated ACOP
- 3.79
- Standby power (PIA)
- 2.0 W
- Compressor
- Fixed speed
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- 47.6 dB(A)
- Outdoor sound power
- 54.8 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Euromatic EUR-9000FX zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 468 | 375 |
| Coldresidential | residential | 2.0 | 1.5 | 201 | 1,110 |
| Mixedcommercial | commercial | β | β | 573 | 204 |
| Mixedresidential | residential | 2.0 | 1.5 | 303 | 441 |
| Hotcommercial | commercial | β | β | 1,233 | 46 |
| Hotresidential | residential | 2.0 | 1.5 | 893 | 72 |
Part-load test points (6 values)
- h__h2_full_cap_power_rated
- 656 W
- h__h3_have_full_cap_results
- No
- h__h2_full_cap_heat_cap_rated
- 2280 W
- c__low_temp_full_cap_power_rated
- 670 W
- c__low_temp_have_full_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 2975 W
New Zealand E3 registration details
- Registration number
- AAC7860
- GEMS registration id
- 157523
- Status
- approved, available (self-reported)
- Registration expires
- 6 November 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.