c/kWh
Energy rating (cooling)
6.5
Heating: 3
Annual electricity use
1,015 kWh
90 cooling + 925 heating
Estimated running cost
$335 / year
$28 / month Β· $3,350 over 10 years
Capacity
2.7 kW cooling
3.3 kW heating

5% less electricity than the median of 177 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 65% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 89% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Westinghouse WSD27HWC-E running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,015$335$3,350
Mixed zone 498$164$1,643
Hot zone 461$152$1,521

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.7 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr7$265

Heat pumps similar to the Westinghouse WSD27HWC-E

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr7$265
Carrier 38QAG026N8/42QAG026N82.8 kW heating2.6 kW cooling822 kWh/yr6.5$271
Aux ASW-H27A4/CAR3DI2.7 kW heating2.6 kW cooling845 kWh/yr7.5$279
TCL TAC-09CHSD/P73.6 kW heating2.6 kW cooling1,226 kWh/yr4$405
Carrier 38QHG026N8/42QHG026N8-12.8 kW heating2.6 kW cooling822 kWh/yr6.5$271
Rinnai HSNRP26B2.7 kW heating2.6 kW cooling805 kWh/yr6$266
Midea MFXP26W/MFXP26N2.7 kW heating2.6 kW cooling805 kWh/yr6$266
Midea MFAB-26WC/MFAB-26NC2.7 kW heating2.6 kW cooling805 kWh/yr6$266

Compare WSD27HWC-E / WSD27HWC-I with another model

Westinghouse WSD27HWC-E specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.65 kW
Cooling power input
0.49 kW
Rated heating capacity (7 Β°C)
3.25 kW
Heating power input
0.70 kW
EER, full load (tested)
5.34
COP, full load (tested)
4.49
Rated AEER
5.37
Rated ACOP
4.60
Standby power (PIA)
1.1 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
56.6 dB(A)
Outdoor sound power
60 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Westinghouse WSD27HWC-E zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––143296
Coldresidential6.53.090925
Mixedcommercial––208158
Mixedresidential6.03.5143355
Hotcommercial––49033
Hotresidential6.54.040952
Part-load test points (23 values)
c__t1_min_cap_power_rated
154 W
h__h1_min_cap_power_rated
191 W
h__h2_ext_cap_power_rated
1088 W
c__t1_half_cap_power_rated
210 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
279 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1100 W
h__h2_ext_cap_heat_cap_rated
3660 W
h__h1_half_cap_heat_cap_rated
1625 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
113 W
c__t1_min_cap_cooling_cap_rated
880 W
c__low_temp_half_cap_power_rated
146 W
c__t1_half_cap_cooling_cap_rated
1200 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1040 W
c__low_temp_half_cap_cooling_cap_rated
1400 W

New Zealand E3 registration details

Registration number
AAC10139
GEMS registration id
179448
Status
approved, available (self-reported)
Registration expires
10 May 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8