c/kWh
Energy rating (cooling)
5
Heating: 2.5
Annual electricity use
1,079 kWh
109 cooling + 970 heating
Estimated running cost
$356 / year
$30 / month Β· $3,561 over 10 years
Capacity
2.6 kW cooling
3.2 kW heating

1% more electricity than the median of 175 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 46% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 87% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Braemar PCHV25D1B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,079$356$3,561
Mixed zone 528$174$1,742
Hot zone 548$181$1,808

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH09KNCA / ASTH09KNCA3.2 kW heating2.5 kW cooling0 kWh/yr–$0
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr7$261

Heat pumps similar to the Braemar PCHV25D1B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr7$265
Carrier 38QAG026N8/42QAG026N82.8 kW heating2.6 kW cooling822 kWh/yr6.5$271
Aux ASW-H27A4/CAR3DI2.7 kW heating2.6 kW cooling845 kWh/yr7.5$279
Carrier 38QHG026N8/42QHG026N8-12.8 kW heating2.6 kW cooling822 kWh/yr6.5$271
Rinnai HSNRP26B2.7 kW heating2.6 kW cooling805 kWh/yr6$266
Midea MFXP26W/MFXP26N2.7 kW heating2.6 kW cooling805 kWh/yr6$266
Westinghouse WSD27HWA-E/WSD27HWA-I3.5 kW heating2.6 kW cooling1,093 kWh/yr6.5$361
Westinghouse WSD27HWB-I/WSD27HWA-E3.5 kW heating2.6 kW cooling1,093 kWh/yr6.5$361

Compare PCHV25D1B/PSHV25D1S with another model

Braemar PCHV25D1B specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.65 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
3.20 kW
Heating power input
–
EER, full load (tested)
4.64
COP, full load (tested)
4.32
Rated AEER
4.57
Rated ACOP
4.27
Standby power (PIA)
1.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
55.2 dB(A)
Outdoor sound power
59.3 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar PCHV25D1B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––179300
Coldresidential5.02.5109970
Mixedcommercial––258154
Mixedresidential4.53.0172356
Hotcommercial––61132
Hotresidential5.04.049850
Part-load test points (20 values)
h__h1_min_cap_power_rated
180 W
h__h2_ext_cap_power_rated
1080 W
c__t1_half_cap_power_rated
225 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
295 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1100 W
h__h2_ext_cap_heat_cap_rated
3200 W
h__h1_half_cap_heat_cap_rated
1700 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
162 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1300 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
1300 W

New Zealand E3 registration details

Registration number
AAC817316357
GEMS registration id
–
Status
approved
Registration expires
20 October 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.