New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Westinghouse WSD27HWB-I/WSD27HWA-E Heat Pump
Westinghouse WSD27HWB-I/WSD27HWA-E is a 2.6 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7557).
- Energy rating (cooling)
- 6.5
- Heating: 3
- Annual electricity use
- 1,093 kWh
- 90 cooling + 1,003 heating
- Estimated running cost
- $361 / year
- $30 / month Β· $3,607 over 10 years
- Capacity
- 2.6 kW cooling
- 3.5 kW heating
2% more electricity than the median of 178 comparable 2.5 kW reverse cycle split system registrations (1,074 kWh a year) in the cold zone. Uses less than 45% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 87% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Westinghouse WSD27HWB-I running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,093 | $361 | $3,607 |
| Mixed zone | 528 | $174 | $1,742 |
| Hot zone | 463 | $153 | $1,528 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr | 4 | $215 | |
| Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr | 6.5 | $256 | |
| Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr | 7 | $261 | |
| Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr | 7 | $261 | |
| Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr | 7 | $265 |
Heat pumps similar to the Westinghouse WSD27HWB-I
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38QRG026N8/42QRG026N82.8 kW heating2.6 kW cooling822 kWh/yr | 6.5 | $271 | |
| Midea MFAB-26WC/MFAB-26NC2.7 kW heating2.6 kW cooling805 kWh/yr | 6 | $266 | |
| Carrier 38QAG026N8/42QAG026N82.8 kW heating2.6 kW cooling822 kWh/yr | 6.5 | $271 | |
| Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr | 7 | $265 | |
| Aux ASW-H27A4/CAR3DI2.7 kW heating2.6 kW cooling845 kWh/yr | 7.5 | $279 | |
| TCL TAC-09CHSD/P73.6 kW heating2.6 kW cooling1,226 kWh/yr | 4 | $405 | |
| Rinnai HSNRP26B2.7 kW heating2.6 kW cooling805 kWh/yr | 6 | $266 | |
| Midea MFXP26W/MFXP26N2.7 kW heating2.6 kW cooling805 kWh/yr | 6 | $266 |
Compare WSD27HWB-I/WSD27HWA-E with another model
Westinghouse WSD27HWB-I specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 2.65 kW
- Cooling power input
- 0.49 kW
- Rated heating capacity (7 Β°C)
- 3.45 kW
- Heating power input
- 0.74 kW
- EER, full load (tested)
- 5.31
- COP, full load (tested)
- 4.93
- Rated AEER
- 5.37
- Rated ACOP
- 4.66
- Standby power (PIA)
- 1.2 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 54.4 dB(A)
- Outdoor sound power
- 56.2 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Westinghouse WSD27HWB-I zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 102 | 325 |
| Coldresidential | residential | 6.5 | 3.0 | 90 | 1,003 |
| Mixedcommercial | commercial | β | β | 180 | 174 |
| Mixedresidential | residential | 6.0 | 3.0 | 142 | 386 |
| Hotcommercial | commercial | β | β | 456 | 36 |
| Hotresidential | residential | 7.0 | 3.5 | 406 | 57 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 174 W
- h__h1_min_cap_power_rated
- 215 W
- h__h2_ext_cap_power_rated
- 1231 W
- c__t1_half_cap_power_rated
- 226 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 296 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 1179 W
- h__h2_ext_cap_heat_cap_rated
- 3890 W
- h__h1_half_cap_heat_cap_rated
- 1684 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 108 W
- c__t1_min_cap_cooling_cap_rated
- 1050 W
- c__low_temp_half_cap_power_rated
- 145 W
- c__t1_half_cap_cooling_cap_rated
- 1277 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 1003 W
- c__low_temp_half_cap_cooling_cap_rated
- 1322 W
Other model numbers on registration AAC7557
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC7557
- GEMS registration id
- 154712
- Status
- approved, available (self-reported)
- Registration expires
- 7 June 2028
- Registered for sale in
- Australia, New Zealand
- Family
- WSD27HWA-E/WSD27HWA-I
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.