c/kWh
Energy rating (cooling)
6
Heating: 3
Annual electricity use
805 kWh
93 cooling + 712 heating
Estimated running cost
$266 / year
$22 / month Β· $2,657 over 10 years
Capacity
2.6 kW cooling
2.7 kW heating

25% less electricity than the median of 178 comparable 2.5 kW reverse cycle split system registrations (1,074 kWh a year) in the cold zone. Uses less than 95% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 91% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea MFXP26W running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 805$266$2,657
Mixed zone 424$140$1,399
Hot zone 473$156$1,561

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256

Heat pumps similar to the Midea MFXP26W

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Westinghouse WSD27HWA-E/WSD27HWA-I3.5 kW heating2.6 kW cooling1,093 kWh/yr6.5$361
Carrier 38QAG026N8/42QAG026N82.8 kW heating2.6 kW cooling822 kWh/yr6.5$271
Westinghouse HSV097HWAE/HSV097HWAI3.5 kW heating2.6 kW cooling1,093 kWh/yr6.5$361
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr7$265
Aux ASW-H27A4/CAR3DI2.7 kW heating2.6 kW cooling845 kWh/yr7.5$279
TCL TAC-09CHSD/P73.6 kW heating2.6 kW cooling1,226 kWh/yr4$405
Rinnai HSNRP26B2.7 kW heating2.6 kW cooling805 kWh/yr6$266
Carrier 38QRG026N8/42QRG026N82.8 kW heating2.6 kW cooling822 kWh/yr6.5$271

Compare MFXP26W/MFXP26N with another model

Midea MFXP26W specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.65 kW
Cooling power input
0.53 kW
Rated heating capacity (7 Β°C)
2.70 kW
Heating power input
0.51 kW
EER, full load (tested)
5.04
COP, full load (tested)
5.16
Rated AEER
4.98
Rated ACOP
5.27
Standby power (PIA)
0.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
55.3 dB(A)
Outdoor sound power
57.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea MFXP26W zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––116231
Coldresidential6.03.093712
Mixedcommercial––193124
Mixedresidential5.53.5148276
Hotcommercial––49326
Hotresidential6.54.043241
Part-load test points (25 values)
c__t1_min_cap_power_rated
180 W
h__h1_min_cap_power_rated
160 W
h__h2_ext_cap_power_rated
1130 W
c__t1_half_cap_power_rated
230 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
220 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
965 W
h__h2_ext_cap_heat_cap_rated
3470 W
h__h1_half_cap_heat_cap_rated
1320 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
115 W
c__t1_min_cap_cooling_cap_rated
990 W
c__low_temp_full_cap_power_rated
484.42 W
c__low_temp_half_cap_power_rated
150 W
c__t1_half_cap_cooling_cap_rated
1300 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1080 W
c__low_temp_full_cap_cooling_cap_rated
2854.0499999999997 W
c__low_temp_half_cap_cooling_cap_rated
1290 W

New Zealand E3 registration details

Registration number
AAC8125
GEMS registration id
159941
Status
approved, available (self-reported)
Registration expires
21 March 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: tradedepot.co.nz. How the derived figures are calculated.