New Zealand Β· costs in NZD
Reverse cycle window / wall air conditioner
Euromatic EUR-9000WAC1 Heat Pump
Euromatic EUR-9000WAC1 is a 2.6 kW reverse cycle window / wall heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7917).
- Energy rating (cooling)
- 1.5
- Heating: 0.5
- Annual electricity use
- 1,567 kWh
- 218 cooling + 1,349 heating
- Estimated running cost
- $517 / year
- $43 / month Β· $5,171 over 10 years
- Capacity
- 2.6 kW cooling
- 2.4 kW heating
1% more electricity than the median of 21 comparable 2.5 kW reverse cycle window / wall registrations (1,546 kWh a year) in the cold zone. Uses less than 29% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 80% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Euromatic EUR-9000WAC1 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,567 | $517 | $5,171 |
| Mixed zone | 853 | $281 | $2,815 |
| Hot zone | 1,051 | $347 | $3,468 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kogan KAWDACR27TD2.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Heller HWA272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Dimplex DCB092.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Bonaire CRC60000272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Euromatic EUR-9000WAC22.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 |
Heat pumps similar to the Euromatic EUR-9000WAC1
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Heller HWA09R2.4 kW heating2.6 kW cooling1,567 kWh/yr | 1.5 | $517 | |
| TECO TWW26HFAT2.4 kW heating2.6 kW cooling1,567 kWh/yr | 1.5 | $517 | |
| Kogan KAVWAC26YB2.9 kW heating2.6 kW cooling1,496 kWh/yr | 2 | $494 | |
| Kogan KAVWAC26YA2.9 kW heating2.6 kW cooling1,496 kWh/yr | 2 | $494 | |
| Dimplex DCB092.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Heller HWA272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Bonaire CRC60000272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Rapta WAC272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 |
Compare EUR-9000WAC1 with another model
Euromatic EUR-9000WAC1 specifications
- Type
- Reverse cycle
- Configuration
- Window / wall
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 2.60 kW
- Cooling power input
- 0.79 kW
- Rated heating capacity (7 Β°C)
- 2.40 kW
- Heating power input
- 0.73 kW
- EER, full load (tested)
- 3.29
- COP, full load (tested)
- 3.29
- Rated AEER
- 3.27
- Rated ACOP
- 3.26
- Standby power (PIA)
- 1.7 W
- Compressor
- Fixed speed
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- 51.8 dB(A)
- Outdoor sound power
- 59.5 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Euromatic EUR-9000WAC1 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 498 | 432 |
| Coldresidential | residential | 1.5 | 0.5 | 218 | 1,349 |
| Mixedcommercial | commercial | β | β | 617 | 229 |
| Mixedresidential | residential | 1.5 | 1.0 | 331 | 522 |
| Hotcommercial | commercial | β | β | 1,336 | 48 |
| Hotresidential | residential | 1.5 | 1.0 | 974 | 77 |
Part-load test points (6 values)
- h__h2_full_cap_power_rated
- 600 W
- h__h3_have_full_cap_results
- No
- h__h2_full_cap_heat_cap_rated
- 1520 W
- c__low_temp_full_cap_power_rated
- 715 W
- c__low_temp_have_full_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 2800 W
New Zealand E3 registration details
- Registration number
- AAC7917
- GEMS registration id
- 158223
- Status
- approved, available (self-reported)
- Registration expires
- 29 November 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 5
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.