c/kWh
Energy rating (cooling)
2
Heating: 1
Annual electricity use
1,496 kWh
186 cooling + 1,310 heating
Estimated running cost
$494 / year
$41 / month Β· $4,937 over 10 years
Capacity
2.6 kW cooling
2.9 kW heating

3% less electricity than the median of 21 comparable 2.5 kW reverse cycle window / wall registrations (1,546 kWh a year) in the cold zone. Uses less than 57% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 81% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kogan KAVWAC26YA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,496$494$4,937
Mixed zone 753$248$2,485
Hot zone 924$305$3,049

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Euromatic EUR-9000WAC22.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Heller HWA272.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Dimplex DCB092.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Bonaire CRC60000272.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Kogan KAWDACR27TD2.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472

Heat pumps similar to the Kogan KAVWAC26YA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Euromatic EUR-9000WAC12.4 kW heating2.6 kW cooling1,567 kWh/yr1.5$517
Heller HWA09R2.4 kW heating2.6 kW cooling1,567 kWh/yr1.5$517
TECO TWW26HFAT2.4 kW heating2.6 kW cooling1,567 kWh/yr1.5$517
Dimplex DCB092.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Bonaire CRC60000272.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Heller HWA272.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Rapta WAC272.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Euromatic EUR-9000WAC22.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472

Compare KAVWAC26YA with another model

Kogan KAVWAC26YA specifications

Type
Reverse cycle
Configuration
Window / wall
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.60 kW
Cooling power input
0.87 kW
Rated heating capacity (7 Β°C)
2.90 kW
Heating power input
0.90 kW
EER, full load (tested)
2.99
COP, full load (tested)
3.29
Rated AEER
2.98
Rated ACOP
3.21
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
59.3 dB(A)
Outdoor sound power
64.9 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kogan KAVWAC26YA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––358382
Coldresidential2.01.01861,310
Mixedcommercial––464191
Mixedresidential2.01.5285468
Hotcommercial––1,14536
Hotresidential2.02.586658
Part-load test points (23 values)
c__t1_min_cap_power_rated
200 W
h__h1_min_cap_power_rated
200 W
c__t1_half_cap_power_rated
400 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
350 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
940 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
940 W
h__h1_half_cap_heat_cap_rated
1560 W
h__h2_full_cap_heat_cap_rated
2100 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
170 W
c__t1_min_cap_cooling_cap_rated
660 W
c__low_temp_full_cap_power_rated
795.1800000000001 W
c__low_temp_half_cap_power_rated
370 W
c__t1_half_cap_cooling_cap_rated
1370 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
840 W
c__low_temp_full_cap_cooling_cap_rated
2800.2 W
c__low_temp_half_cap_cooling_cap_rated
1480 W

Other model numbers on registration AAC6921

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC6921
GEMS registration id
149268
Status
approved, available (self-reported)
Registration expires
4 September 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
KAVWAC26Y*
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 5