New Zealand Β· costs in NZD

Reverse cycle window / wall air conditioner
Kogan KAVWAC26YA Heat Pump
Kogan KAVWAC26YA is a 2.6 kW reverse cycle window / wall heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC6921).
- Energy rating (cooling)
- 2
- Heating: 1
- Annual electricity use
- 1,496 kWh
- 186 cooling + 1,310 heating
- Estimated running cost
- $494 / year
- $41 / month Β· $4,937 over 10 years
- Capacity
- 2.6 kW cooling
- 2.9 kW heating
3% less electricity than the median of 21 comparable 2.5 kW reverse cycle window / wall registrations (1,546 kWh a year) in the cold zone. Uses less than 57% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 81% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Kogan KAVWAC26YA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,496 | $494 | $4,937 |
| Mixed zone | 753 | $248 | $2,485 |
| Hot zone | 924 | $305 | $3,049 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Euromatic EUR-9000WAC22.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Heller HWA272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Dimplex DCB092.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Bonaire CRC60000272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Kogan KAWDACR27TD2.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 |
Heat pumps similar to the Kogan KAVWAC26YA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Euromatic EUR-9000WAC12.4 kW heating2.6 kW cooling1,567 kWh/yr | 1.5 | $517 | |
| Heller HWA09R2.4 kW heating2.6 kW cooling1,567 kWh/yr | 1.5 | $517 | |
| TECO TWW26HFAT2.4 kW heating2.6 kW cooling1,567 kWh/yr | 1.5 | $517 | |
| Dimplex DCB092.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Bonaire CRC60000272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Heller HWA272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Rapta WAC272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Euromatic EUR-9000WAC22.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 |
Compare KAVWAC26YA with another model
Kogan KAVWAC26YA specifications
- Type
- Reverse cycle
- Configuration
- Window / wall
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 2.60 kW
- Cooling power input
- 0.87 kW
- Rated heating capacity (7 Β°C)
- 2.90 kW
- Heating power input
- 0.90 kW
- EER, full load (tested)
- 2.99
- COP, full load (tested)
- 3.29
- Rated AEER
- 2.98
- Rated ACOP
- 3.21
- Standby power (PIA)
- 1.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- 59.3 dB(A)
- Outdoor sound power
- 64.9 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Kogan KAVWAC26YA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 358 | 382 |
| Coldresidential | residential | 2.0 | 1.0 | 186 | 1,310 |
| Mixedcommercial | commercial | β | β | 464 | 191 |
| Mixedresidential | residential | 2.0 | 1.5 | 285 | 468 |
| Hotcommercial | commercial | β | β | 1,145 | 36 |
| Hotresidential | residential | 2.0 | 2.5 | 866 | 58 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 200 W
- h__h1_min_cap_power_rated
- 200 W
- c__t1_half_cap_power_rated
- 400 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 350 W
- h__h1_have_min_cap_results
- Yes
- h__h2_full_cap_power_rated
- 940 W
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 940 W
- h__h1_half_cap_heat_cap_rated
- 1560 W
- h__h2_full_cap_heat_cap_rated
- 2100 W
- h__h2_is_capable_extended_load
- No
- c__low_temp_min_cap_power_rated
- 170 W
- c__t1_min_cap_cooling_cap_rated
- 660 W
- c__low_temp_full_cap_power_rated
- 795.1800000000001 W
- c__low_temp_half_cap_power_rated
- 370 W
- c__t1_half_cap_cooling_cap_rated
- 1370 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 840 W
- c__low_temp_full_cap_cooling_cap_rated
- 2800.2 W
- c__low_temp_half_cap_cooling_cap_rated
- 1480 W
Other model numbers on registration AAC6921
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC6921
- GEMS registration id
- 149268
- Status
- approved, available (self-reported)
- Registration expires
- 4 September 2027
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- KAVWAC26Y*
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 5
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.