c/kWh
Energy rating (cooling)
1.5
Heating: 0.5
Annual electricity use
1,567 kWh
218 cooling + 1,349 heating
Estimated running cost
$517 / year
$43 / month Β· $5,171 over 10 years
Capacity
2.6 kW cooling
2.4 kW heating

1% more electricity than the median of 21 comparable 2.5 kW reverse cycle window / wall registrations (1,546 kWh a year) in the cold zone. Uses less than 29% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 80% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Heller HWA09R running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,567$517$5,171
Mixed zone 853$281$2,815
Hot zone 1,051$347$3,468

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Euromatic EUR-9000WAC22.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Heller HWA272.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Dimplex DCB092.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Bonaire CRC60000272.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Kogan KAWDACR27TD2.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472

Heat pumps similar to the Heller HWA09R

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Euromatic EUR-9000WAC12.4 kW heating2.6 kW cooling1,567 kWh/yr1.5$517
TECO TWW26HFAT2.4 kW heating2.6 kW cooling1,567 kWh/yr1.5$517
Kogan KAVWAC26YC2.9 kW heating2.6 kW cooling1,496 kWh/yr2$494
Kogan KAVWAC26YA2.9 kW heating2.6 kW cooling1,496 kWh/yr2$494
Euromatic EUR-9000WAC22.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Dimplex DCB092.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Rapta WAC272.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472
Bonaire CRC60000272.4 kW heating2.7 kW cooling1,431 kWh/yr1.5$472

Compare HWA09R with another model

Heller HWA09R specifications

Type
Reverse cycle
Configuration
Window / wall
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.60 kW
Cooling power input
0.79 kW
Rated heating capacity (7 Β°C)
2.40 kW
Heating power input
0.73 kW
EER, full load (tested)
3.29
COP, full load (tested)
3.29
Rated AEER
3.27
Rated ACOP
3.26
Standby power (PIA)
1.7 W
Compressor
Fixed speed
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
51.8 dB(A)
Outdoor sound power
59.5 dB(A)
Demand response (AS/NZS 4755)
No
Dimensions (WΓ—HΓ—D)
600 Γ— 560 Γ— 380 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Heller HWA09R zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––498432
Coldresidential1.50.52181,349
Mixedcommercial––617229
Mixedresidential1.51.0331522
Hotcommercial––1,33648
Hotresidential1.51.097477
Part-load test points (5 values)
h__h2_full_cap_power_rated
600 W
h__h2_full_cap_heat_cap_rated
1520 W
c__low_temp_full_cap_power_rated
715 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
2800 W

New Zealand E3 registration details

Registration number
AAC6820
GEMS registration id
147788
Status
approved, available (self-reported)
Registration expires
14 July 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 5

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gafcontrol.com.au. How the derived figures are calculated.