c/kWh
Energy rating (cooling)
2
Heating: 1.5
Annual electricity use
18,672 kWh
2,540 cooling + 16,132 heating
Estimated running cost
$6,162 / year
$513 / month Β· $61,618 over 10 years
Capacity
40 kW cooling
40 kW heating

About the same electricity as the median of 6 comparable 40 kW reverse cycle ducted multi-split / vrf registrations (18,672 kWh a year) in the cold zone. Uses less than 33% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 7% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree GMV-VQ400WM running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 18,672$6,162$61,618
Mixed zone 9,788$3,230$32,300
Hot zone 11,415$3,767$37,670

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 40 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Gree GMV-400WM/C-X(A)40 kW heating40 kW cooling17,377 kWh/yr2.5$5,734
Braemar MCHX400D323B40 kW heating40 kW cooling17,377 kWh/yr2.5$5,734

Heat pumps similar to the Gree GMV-VQ400WM

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar MCRX400D323B40 kW heating40 kW cooling18,672 kWh/yr2$6,162
Panasonic U-14ME2R8E45 kW heating40 kW cooling22,669 kWh/yr3.5$7,481
Haier AV14IMAURA45 kW heating40 kW cooling25,173 kWh/yr1.5$8,307
Panasonic U-14ME2R845 kW heating40 kW cooling22,669 kWh/yr3.5$7,481
Braemar MCHX400D323B40 kW heating40 kW cooling17,377 kWh/yr2.5$5,734

Other Gree models of similar capacity

ModelStarsEst. cost / yrCompare
Gree GMV-400WM/C-X(A)40 kW heating40 kW cooling17,377 kWh/yr2.5$5,734

Compare GMV-VQ400WM/C-X(A) with another model

Gree GMV-VQ400WM specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
40.00 kW
Cooling power input
10.20 kW
Rated heating capacity (7 Β°C)
40.00 kW
Heating power input
9.90 kW
EER, full load (tested)
3.88
COP, full load (tested)
4.01
Rated AEER
3.74
Rated ACOP
3.85
Standby power (PIA)
145.6 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree GMV-VQ400WM zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5,0685,239
Coldresidential2.01.52,54016,132
Mixedcommercial––6,2902,772
Mixedresidential2.52.03,8335,955
Hotcommercial––13,549781
Hotresidential3.02.510,2781,137
Part-load test points (20 values)
h__h2_ext_cap_power_rated
14900 W
c__t1_half_cap_power_rated
3750 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
4250 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
33500 W
h__h1_half_cap_heat_cap_rated
20000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
9322.800000000001 W
c__low_temp_half_cap_power_rated
3427.5 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
20000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
43080 W
c__low_temp_half_cap_cooling_cap_rated
21540 W

New Zealand E3 registration details

Registration number
AAC6706
GEMS registration id
146962
Status
approved, available (self-reported)
Registration expires
16 May 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 21

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.