c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
1,839 kWh
256 cooling + 1,583 heating
Estimated running cost
$607 / year
$51 / month Β· $6,069 over 10 years
Capacity
4.6 kW cooling
4.7 kW heating

15% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 95% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 78% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,839$607$6,069
Mixed zone 994$328$3,280
Hot zone 1,239$409$4,089

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 4.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518

Heat pumps similar to the Gree

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Toshiba RAS-16E2AVRG-A / RAS-B16E2KVRG-A5.5 kW heating4.6 kW cooling2,922 kWh/yr3$964
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Mitsubishi Heavy Industries SRC45ZSPA-W / SRK45ZSPA-W5 kW heating4.5 kW cooling2,095 kWh/yr2.5$691
LG WS18TWU / WS18TWN5.9 kW heating4.8 kW cooling2,712 kWh/yr3.5$895
LG AS18S1U / AS18S1N5.2 kW heating4.8 kW cooling2,188 kWh/yr3.5$722
Midea MFAG51VA-W/MFCS50VA-N5.5 kW heating4.9 kW cooling2,122 kWh/yr4.5$700

Other Gree models of similar capacity

ModelStarsEst. cost / yrCompare
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606

Compare GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNC8B/I with another model

Gree specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
4.60 kW
Cooling power input
1.15 kW
Rated heating capacity (7 Β°C)
4.70 kW
Heating power input
1.20 kW
EER, full load (tested)
4.01
COP, full load (tested)
4.19
Rated AEER
3.94
Rated ACOP
3.86
Standby power (PIA)
5.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
59.7 dB(A)
Outdoor sound power
67.4 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––499510
Coldresidential3.02.02561,583
Mixedcommercial––643270
Mixedresidential3.02.5393601
Hotcommercial––1,50662
Hotresidential3.53.01,14396
Part-load test points (23 values)
c__t1_min_cap_power_rated
280 W
h__h2_ext_cap_power_rated
2050 W
c__t1_half_cap_power_rated
440 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
480 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5200 W
h__h1_half_cap_heat_cap_rated
2550 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
250 W
c__t1_min_cap_cooling_cap_rated
900 W
c__low_temp_full_cap_power_rated
1051.1000000000001 W
c__low_temp_half_cap_power_rated
402.16 W
c__t1_half_cap_cooling_cap_rated
2200 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
1400 W
c__low_temp_full_cap_cooling_cap_rated
4954.2 W
c__low_temp_half_cap_cooling_cap_rated
2369.4 W

Other model numbers on registration AAC6283

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC6283
GEMS registration id
142230
Status
approved, available (self-reported)
Registration expires
14 October 2026
Registered for sale in
Australia, Fiji, New Zealand
Family
GWH15QDXE
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.