c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
2,208 kWh
267 cooling + 1,941 heating
Estimated running cost
$729 / year
$61 / month Β· $7,286 over 10 years
Capacity
5.2 kW cooling
5.6 kW heating

3% more electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 41% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 73% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,208$729$7,286
Mixed zone 1,122$370$3,703
Hot zone 1,325$437$4,373

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNA1A/I4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the Gree

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Akai AK-TP525.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Ers Tech ERS-AC52F015.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Aux ASW-H52A4/CAR3DI5.2 kW heating5.2 kW cooling2,056 kWh/yr5$678
TCL TAC-18CHSD/TPH11IT5.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608
Braemar TCHV50T1S/TSHV50T1S5.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675
Spt AW052C-1 / AW052E5.6 kW heating5.2 kW cooling2,104 kWh/yr4.5$694
Bonaire CRC6911050/CRC69111505.2 kW heating5.2 kW cooling2,046 kWh/yr3.5$675

Compare GWH18AADXE-K6DNA1A/O / GWH18AADXE-K6DN**A/I with another model

Gree specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.20 kW
Cooling power input
1.35 kW
Rated heating capacity (7 Β°C)
5.60 kW
Heating power input
1.40 kW
EER, full load (tested)
3.87
COP, full load (tested)
4.11
Rated AEER
3.79
Rated ACOP
3.94
Standby power (PIA)
6.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
63.2 dB(A)
Outdoor sound power
66.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––477616
Coldresidential3.52.02671,941
Mixedcommercial––623317
Mixedresidential3.52.5412710
Hotcommercial––1,58372
Hotresidential4.03.01,214111
Part-load test points (23 values)
c__t1_min_cap_power_rated
210 W
h__h2_ext_cap_power_rated
2000 W
c__t1_half_cap_power_rated
500 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
550 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5220 W
h__h1_half_cap_heat_cap_rated
2970 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
190 W
c__t1_min_cap_cooling_cap_rated
1010 W
c__low_temp_full_cap_power_rated
1233.9 W
c__low_temp_half_cap_power_rated
457 W
c__t1_half_cap_cooling_cap_rated
2600 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
1640 W
c__low_temp_full_cap_cooling_cap_rated
5600.4 W
c__low_temp_half_cap_cooling_cap_rated
2800.2 W

Other model numbers on registration AAC6406

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC6406
GEMS registration id
143794
Status
approved, available (self-reported)
Registration expires
12 January 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
GWH18AADXE-K6DNA1A/O / GWH18AADXE-K6DN**A/I
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.