New Zealand Β· costs in NZD
Reverse cycle split system air conditioner, wall hung
Gree GWH28AGEXH-K6DNA1E/O / GWH28QEXH-K6DNC8E/I Heat Pump
Gree GWH28AGEXH-K6DNA1E/O / GWH28QEXH-K6DNC8E/I is a 8.5 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC6796).
- Energy rating (cooling)
- 4
- Heating: 2
- Annual electricity use
- 3,550 kWh
- 386 cooling + 3,164 heating
- Estimated running cost
- $1,172 / year
- $98 / month Β· $11,715 over 10 years
- Capacity
- 8.5 kW cooling
- 9 kW heating
2% less electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 68% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 53% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Gree running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,550 | $1,172 | $11,715 |
| Mixed zone | 1,750 | $578 | $5,775 |
| Hot zone | 1,881 | $621 | $6,207 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 8.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kogan KASSSAC80HF8.2 kW heating8 kW cooling3,283 kWh/yr | 4.5 | $1,083 | |
| Kogan KASSSAC80HA8.2 kW heating8 kW cooling3,283 kWh/yr | 4.5 | $1,083 | |
| Comfee CASG-XG80/CASN-XG808.2 kW heating7.9 kW cooling3,328 kWh/yr | 3.5 | $1,098 | |
| Midea MFXS81WA/MFXS81NA8 kW heating7.6 kW cooling3,333 kWh/yr | 3.5 | $1,100 | |
| Midea MFXP80WA/MFXP80NA8 kW heating7.6 kW cooling3,333 kWh/yr | 3.5 | $1,100 |
Heat pumps similar to the Gree
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Haier 1U85XAGFRA / AS85PFGHRA9.5 kW heating8.5 kW cooling3,660 kWh/yr | 3.5 | $1,208 | |
| Braemar WCHV85D1T/WSHV85D1T9 kW heating8.5 kW cooling3,578 kWh/yr | 4 | $1,181 | |
| Fujitsu AOTH30KNTA/ASTH30KNTA9 kW heating8.5 kW cooling3,477 kWh/yr | 4 | $1,147 | |
| Actron Air WRC-085CS / WRE-085CS9.4 kW heating8.5 kW cooling5,239 kWh/yr | 3.5 | $1,729 | |
| Fujitsu AOTH30KMTD/ASTH30KMTD9 kW heating8.5 kW cooling3,477 kWh/yr | 4 | $1,147 | |
| LG WH30SRU-18 / WH30SRN-189 kW heating8.5 kW cooling3,731 kWh/yr | 3 | $1,231 | |
| LG LS30S0U DX6ALAP/LS30S0N DX6ALAP8.7 kW heating8.6 kW cooling3,679 kWh/yr | 3 | $1,214 |
Other Gree models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Gree GWH28QEXH-K6DNA1E/O / GWH28QEXH-K6DNC8E/I9 kW heating8.5 kW cooling3,550 kWh/yr | 4 | $1,172 |
Compare GWH28AGEXH-K6DNA1E/O / GWH28QEXH-K6DNC8E/I with another model
Gree specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 8.50 kW
- Cooling power input
- 2.30 kW
- Rated heating capacity (7 Β°C)
- 9.00 kW
- Heating power input
- 2.55 kW
- EER, full load (tested)
- 3.73
- COP, full load (tested)
- 3.47
- Rated AEER
- 3.67
- Rated ACOP
- 3.50
- Standby power (PIA)
- 6.2 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 64.6 dB(A)
- Outdoor sound power
- 71 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Gree zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 256 | 971 |
| Coldresidential | residential | 4.0 | 2.0 | 386 | 3,164 |
| Mixedcommercial | commercial | β | β | 655 | 484 |
| Mixedresidential | residential | 4.0 | 2.5 | 617 | 1,133 |
| Hotcommercial | commercial | β | β | 1,697 | 103 |
| Hotresidential | residential | 4.5 | 3.5 | 1,719 | 162 |
Part-load test points (28 values)
- h__h1_min_cap_power_rated
- 513 W
- h__h2_ext_cap_power_rated
- 2975 W
- h__h3_ext_cap_power_rated
- 2950 W
- c__t1_half_cap_power_rated
- 1100 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 888 W
- h__h1_have_min_cap_results
- Yes
- h__h2_half_cap_power_rated
- 907 W
- h__h3_half_cap_power_rated
- 1490 W
- h__h3_have_ext_cap_results
- Yes
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- Yes
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- Yes
- h__h1_min_cap_heat_cap_rated
- 2810 W
- h__h2_ext_cap_heat_cap_rated
- 7620 W
- h__h3_ext_cap_heat_cap_rated
- 7200 W
- h__h1_half_cap_heat_cap_rated
- 4345 W
- h__h2_half_cap_heat_cap_rated
- 3220 W
- h__h3_half_cap_heat_cap_rated
- 3010 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 2099.458 W
- c__low_temp_half_cap_power_rated
- 620 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 4330 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 9154.5 W
- c__low_temp_half_cap_cooling_cap_rated
- 4265 W
Other model numbers on registration AAC6796
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC6796
- GEMS registration id
- 147820
- Status
- approved, available (self-reported)
- Registration expires
- 30 June 2027
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- GWH28AGEXH-K6DNA1E/O / GWH28QEXH-K6DN**E/I
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.