New Zealand Β· costs in NZD
Reverse cycle split system air conditioner
Gree GWH28ATEXF-K6DNA1A/O / GWH28ATEXF-K6DNA2A/I Heat Pump
Gree GWH28ATEXF-K6DNA1A/O / GWH28ATEXF-K6DNA2A/I is a 8.2 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8258).
- Energy rating (cooling)
- 3.5
- Heating: 2
- Annual electricity use
- 3,690 kWh
- 422 cooling + 3,268 heating
- Estimated running cost
- $1,218 / year
- $101 / month Β· $12,177 over 10 years
- Capacity
- 8.2 kW cooling
- 9 kW heating
2% more electricity than the median of 117 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 40% of them.
Across all 3,566 air conditioner registrations sold in Australia, it uses less than 51% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Gree running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,690 | $1,218 | $12,177 |
| Mixed zone | 1,784 | $589 | $5,887 |
| Hot zone | 2,033 | $671 | $6,709 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 8.2 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Spt AW073C-1 / AW073E8.1 kW heating7.3 kW cooling3,037 kWh/yr | 4 | $1,002 | |
| Westinghouse HSV247HWAE/HSV247HWAI8.3 kW heating7.3 kW cooling3,063 kWh/yr | 4 | $1,011 | |
| Westinghouse WSD73HWA-E/WSD73HWA-I8.3 kW heating7.3 kW cooling3,063 kWh/yr | 4 | $1,011 | |
| Kogan KASSSAC80HE8.2 kW heating8 kW cooling3,283 kWh/yr | 4.5 | $1,083 | |
| Kogan KASSSAC80HC8.2 kW heating8 kW cooling3,283 kWh/yr | 4.5 | $1,083 |
Heat pumps similar to the Gree
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Bonaire CRC6911082/CRC69111828.5 kW heating8.2 kW cooling3,401 kWh/yr | 3.5 | $1,122 | |
| Braemar TCHV80T1S/TSHV80T1S8.5 kW heating8.2 kW cooling3,401 kWh/yr | 3.5 | $1,122 | |
| Kogan KASHSAC80TD8.5 kW heating8.2 kW cooling3,401 kWh/yr | 3.5 | $1,122 | |
| Ers Tech ERS-AC82F018.5 kW heating8.2 kW cooling3,401 kWh/yr | 3.5 | $1,122 | |
| TCL TAC-28CHSD/TPH11IT8.5 kW heating8.2 kW cooling3,401 kWh/yr | 3.5 | $1,122 | |
| Kogan KASHSAC80TA8.5 kW heating8.2 kW cooling3,401 kWh/yr | 3.5 | $1,122 | |
| Bonaire STH082S1AE/STH082S1AI8.4 kW heating8.2 kW cooling3,414 kWh/yr | 3.5 | $1,127 | |
| Braemar TCHV08T1S/TSHV08T1S8.4 kW heating8.2 kW cooling3,414 kWh/yr | 3.5 | $1,127 |
Compare GWH28ATEXF-K6DNA1A/O / GWH28ATEXF-K6DNA2A/I with another model
Gree specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 8.20 kW
- Cooling power input
- β
- Rated heating capacity (7 Β°C)
- 9.00 kW
- Heating power input
- β
- EER, full load (tested)
- 3.47
- COP, full load (tested)
- 3.41
- Rated AEER
- 3.27
- Rated ACOP
- 3.37
- Standby power (PIA)
- 6.2 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 67.8 dB(A)
- Outdoor sound power
- 68.9 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Gree zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 638 | 1,019 |
| Coldresidential | residential | 3.5 | 2.0 | 422 | 3,268 |
| Mixedcommercial | commercial | β | β | 929 | 426 |
| Mixedresidential | residential | 3.5 | 2.5 | 675 | 1,109 |
| Hotcommercial | commercial | β | β | 2,182 | 87 |
| Hotresidential | residential | 4.0 | 3.5 | 1,875 | 158 |
Part-load test points (27 values)
- c__t1_min_cap_power_rated
- 620 W
- h__h2_ext_cap_power_rated
- 2500 W
- h__h3_ext_cap_power_rated
- 3200 W
- c__t1_half_cap_power_rated
- 1300 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 940 W
- h__h1_have_min_cap_results
- No
- h__h2_half_cap_power_rated
- 930 W
- h__h3_half_cap_power_rated
- 1800 W
- h__h3_have_ext_cap_results
- Yes
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- Yes
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- Yes
- h__h2_ext_cap_heat_cap_rated
- 6500 W
- h__h3_ext_cap_heat_cap_rated
- 7000 W
- h__h1_half_cap_heat_cap_rated
- 4500 W
- h__h2_half_cap_heat_cap_rated
- 3350 W
- h__h3_half_cap_heat_cap_rated
- 2830 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 535 W
- c__t1_min_cap_cooling_cap_rated
- 1900 W
- c__low_temp_half_cap_power_rated
- 700 W
- c__t1_half_cap_cooling_cap_rated
- 4100 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3800 W
- c__low_temp_half_cap_cooling_cap_rated
- 4300 W
Related Gree model numbers starting with GWH28ATEXF
1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.
| Model | Registration | Stars | kWh / yr | Registration expires |
|---|---|---|---|---|
| GWH28ATEXF-K6DNA1A/O / GWH28ATEXF-K6DNA1A/I | AAC7761 | 3.5 | 3,677 | 4 September 2028 |
Other model numbers on registration AAC8258
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC8258
- GEMS registration id
- β
- Status
- approved
- Registration expires
- 22 May 2029
- Registered for sale in
- Australia, New Zealand
- Family
- GWH28ATEXF
- Regulatory standard
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.