c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
4,445 kWh
513 cooling + 3,932 heating
Estimated running cost
$1,467 / year
$122 / month Β· $14,669 over 10 years
Capacity
10 kW cooling
11 kW heating

About the same electricity as the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 50% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 44% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,445$1,467$14,669
Mixed zone 2,148$709$7,088
Hot zone 2,553$842$8,425

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Kogan KASSSAC90HF9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Kogan KASSSAC90HA9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210

Heat pumps similar to the Gree

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kinghome KWH100ATBXB-K6DNA1/O / KWH100ATBXB-K6DNA1/I11 kW heating10 kW cooling4,445 kWh/yr3.5$1,467
Hitachi PAS-4.0UFASNQ1 / PPK-4.0UFA1NQ11.5 kW heating10 kW cooling4,677 kWh/yr3$1,543
Braemar CCHV100D1S/CSHV100D1S11 kW heating10 kW cooling4,445 kWh/yr3.5$1,467
Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling4,000 kWh/yr3.5$1,320
Daikin RZAV100FY1 / FCA100CVMA12 kW heating10 kW cooling3,792 kWh/yr4$1,251
Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114

Compare GWH36AWFXH-K6DNA1A/O / GWH36AWFXH-K6DNA1A/I with another model

Gree specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
2.81 kW
Rated heating capacity (7 Β°C)
11.00 kW
Heating power input
3.24 kW
EER, full load (tested)
3.67
COP, full load (tested)
3.54
Rated AEER
3.53
Rated ACOP
3.37
Standby power (PIA)
5.9 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
70.3 dB(A)
Outdoor sound power
72.9 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––9281,182
Coldresidential3.52.05133,932
Mixedcommercial––1,247478
Mixedresidential3.52.58041,344
Hotcommercial––3,096100
Hotresidential4.03.52,367186
Part-load test points (27 values)
c__t1_min_cap_power_rated
800 W
h__h2_ext_cap_power_rated
3500 W
h__h3_ext_cap_power_rated
3650 W
c__t1_half_cap_power_rated
1180 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1060 W
h__h1_have_min_cap_results
No
h__h2_half_cap_power_rated
1150 W
h__h3_half_cap_power_rated
2100 W
h__h3_have_ext_cap_results
Yes
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
Yes
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
Yes
h__h2_ext_cap_heat_cap_rated
8900 W
h__h3_ext_cap_heat_cap_rated
7900 W
h__h1_half_cap_heat_cap_rated
5200 W
h__h2_half_cap_heat_cap_rated
3800 W
h__h3_half_cap_heat_cap_rated
4100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
670 W
c__t1_min_cap_cooling_cap_rated
2300 W
c__low_temp_half_cap_power_rated
845 W
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
4900 W
c__low_temp_half_cap_cooling_cap_rated
5000 W

New Zealand E3 registration details

Registration number
AAC8883
GEMS registration id
169645
Status
approved, available (self-reported)
Registration expires
21 May 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.