New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Hitachi PAS-4.0UFASNQ1 / PPK-4.0UFA1NQ Heat Pump
Hitachi PAS-4.0UFASNQ1 / PPK-4.0UFA1NQ is a 10 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8595).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 4,677 kWh
- 562 cooling + 4,115 heating
- Estimated running cost
- $1,543 / year
- $129 / month Β· $15,434 over 10 years
- Capacity
- 10 kW cooling
- 11.5 kW heating
5% more electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 38% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 42% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Hitachi running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,677 | $1,543 | $15,434 |
| Mixed zone | 2,387 | $788 | $7,877 |
| Hot zone | 2,741 | $905 | $9,045 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Kogan KASSSAC90H*9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 | |
| Kogan KASSSAC90HB9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 |
Heat pumps similar to the Hitachi
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kinghome KWH100ATBXB-K6DNA1/O / KWH100ATBXB-K6DNA1/I11 kW heating10 kW cooling4,445 kWh/yr | 3.5 | $1,467 | |
| Braemar CCHV100D1S/CSHV100D1S11 kW heating10 kW cooling4,445 kWh/yr | 3.5 | $1,467 | |
| Gree GWH36AWFXH-K6DNA1A/O / GWH36AWFXH-K6DNA1A/I11 kW heating10 kW cooling4,445 kWh/yr | 3.5 | $1,467 | |
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Daikin RZAV100FY1 / FCA100CVMA12 kW heating10 kW cooling3,792 kWh/yr | 4 | $1,251 | |
| Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 |
Other Hitachi models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hitachi PAS-4.0UFASMQ1 / PPK-4.0UFA1NQ11.5 kW heating10 kW cooling4,901 kWh/yr | 2.5 | $1,617 |
Compare PAS-4.0UFASNQ1 / PPK-4.0UFA1NQ with another model
Hitachi specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 10.00 kW
- Cooling power input
- 2.54 kW
- Rated heating capacity (7 Β°C)
- 11.50 kW
- Heating power input
- 3.08 kW
- EER, full load (tested)
- 3.87
- COP, full load (tested)
- 3.65
- Rated AEER
- 3.88
- Rated ACOP
- 3.69
- Standby power (PIA)
- 12.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hitachi zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,213 | 1,298 |
| Coldresidential | residential | 3.0 | 2.0 | 562 | 4,115 |
| Mixedcommercial | commercial | β | β | 1,522 | 672 |
| Mixedresidential | residential | 3.0 | 2.5 | 872 | 1,515 |
| Hotcommercial | commercial | β | β | 3,360 | 150 |
| Hotresidential | residential | 3.5 | 3.0 | 2,509 | 232 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 4000 W
- c__t1_half_cap_power_rated
- 960 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1100 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 10600 W
- h__h1_half_cap_heat_cap_rated
- 5750 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 2321.56 W
- c__low_temp_half_cap_power_rated
- 877.44 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 5000 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 10770 W
- c__low_temp_half_cap_cooling_cap_rated
- 5385 W
New Zealand E3 registration details
- Registration number
- AAC8595
- GEMS registration id
- 166496
- Status
- approved, available (self-reported)
- Registration expires
- 10 February 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11