New Zealand Β· costs in NZD
Reverse cycle split system air conditioner, wall hung
Kinghome KWH100ATBXB-K6DNA1/O / KWH100ATBXB-K6DNA1/I Heat Pump
Kinghome KWH100ATBXB-K6DNA1/O / KWH100ATBXB-K6DNA1/I is a 10 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9439).
- Energy rating (cooling)
- 3.5
- Heating: 2
- Annual electricity use
- 4,445 kWh
- 513 cooling + 3,932 heating
- Estimated running cost
- $1,467 / year
- $122 / month Β· $14,669 over 10 years
- Capacity
- 10 kW cooling
- 11 kW heating
About the same electricity as the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 50% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 44% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Kinghome running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,445 | $1,467 | $14,669 |
| Mixed zone | 2,148 | $709 | $7,088 |
| Hot zone | 2,553 | $842 | $8,425 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Kogan KASSSAC90HA9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 | |
| Kogan KASSSAC90HF9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 |
Heat pumps similar to the Kinghome
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Gree GWH36AWFXH-K6DNA1A/O / GWH36AWFXH-K6DNA1A/I11 kW heating10 kW cooling4,445 kWh/yr | 3.5 | $1,467 | |
| Hitachi PAS-4.0UFASNQ1 / PPK-4.0UFA1NQ11.5 kW heating10 kW cooling4,677 kWh/yr | 3 | $1,543 | |
| Braemar CCHV100D1S/CSHV100D1S11 kW heating10 kW cooling4,445 kWh/yr | 3.5 | $1,467 | |
| Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling4,000 kWh/yr | 3.5 | $1,320 | |
| Daikin RZAV100FY1 / FCA100CVMA12 kW heating10 kW cooling3,792 kWh/yr | 4 | $1,251 | |
| Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 |
Compare KWH100ATBXB-K6DNA1/O / KWH100ATBXB-K6DNA1/I with another model
Kinghome specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 10.00 kW
- Cooling power input
- 2.81 kW
- Rated heating capacity (7 Β°C)
- 11.00 kW
- Heating power input
- 3.24 kW
- EER, full load (tested)
- 3.67
- COP, full load (tested)
- 3.54
- Rated AEER
- 3.53
- Rated ACOP
- 3.37
- Standby power (PIA)
- 5.9 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 70.1 dB(A)
- Outdoor sound power
- 72.9 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Kinghome zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 928 | 1,182 |
| Coldresidential | residential | 3.5 | 2.0 | 513 | 3,932 |
| Mixedcommercial | commercial | β | β | 1,247 | 478 |
| Mixedresidential | residential | 3.5 | 2.5 | 804 | 1,344 |
| Hotcommercial | commercial | β | β | 3,096 | 100 |
| Hotresidential | residential | 4.0 | 3.5 | 2,367 | 186 |
Part-load test points (27 values)
- c__t1_min_cap_power_rated
- 800 W
- h__h2_ext_cap_power_rated
- 3500 W
- h__h3_ext_cap_power_rated
- 3650 W
- c__t1_half_cap_power_rated
- 1180 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1060 W
- h__h1_have_min_cap_results
- No
- h__h2_half_cap_power_rated
- 1150 W
- h__h3_half_cap_power_rated
- 2100 W
- h__h3_have_ext_cap_results
- Yes
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- Yes
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- Yes
- h__h2_ext_cap_heat_cap_rated
- 8900 W
- h__h3_ext_cap_heat_cap_rated
- 7900 W
- h__h1_half_cap_heat_cap_rated
- 5200 W
- h__h2_half_cap_heat_cap_rated
- 3800 W
- h__h3_half_cap_heat_cap_rated
- 4100 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 670 W
- c__t1_min_cap_cooling_cap_rated
- 2300 W
- c__low_temp_half_cap_power_rated
- 845 W
- c__t1_half_cap_cooling_cap_rated
- 5000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 4900 W
- c__low_temp_half_cap_cooling_cap_rated
- 5000 W
New Zealand E3 registration details
- Registration number
- AAC9439
- GEMS registration id
- 173133
- Status
- approved, available (self-reported)
- Registration expires
- 17 September 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.