New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, cassette
Hitachi PAS-6.5UFASMQ1 / PCI-6.5UFA1NQ Heat Pump
Hitachi PAS-6.5UFASMQ1 / PCI-6.5UFA1NQ is a 16 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8083).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 7,190 kWh
- 925 cooling + 6,265 heating
- Estimated running cost
- $2,373 / year
- $198 / month Β· $23,727 over 10 years
- Capacity
- 16 kW cooling
- 18 kW heating
Only 2 comparable registrations in this cohort, so no percentile is shown.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 23% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Hitachi running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 7,190 | $2,373 | $23,727 |
| Mixed zone | 3,688 | $1,217 | $12,170 |
| Hot zone | 4,563 | $1,506 | $15,058 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 16 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air URC-140DS / CRE-140DS14.5 kW heating14.1 kW cooling5,661 kWh/yr | 3.5 | $1,868 | |
| Midea UCMI140OC/CASMI140IC14.5 kW heating14.1 kW cooling5,694 kWh/yr | 3.5 | $1,879 |
Heat pumps similar to the Hitachi
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea UCMI140OC/CASMI140IC14.5 kW heating14.1 kW cooling5,694 kWh/yr | 3.5 | $1,879 | |
| Actron Air URC-140DS / CRE-140DS14.5 kW heating14.1 kW cooling5,661 kWh/yr | 3.5 | $1,868 |
Other Hitachi models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hitachi PAS-6.5UFASNQ1 / PCI-6.5UFA1NQ18 kW heating16 kW cooling7,471 kWh/yr | 3 | $2,465 |
Compare PAS-6.5UFASMQ1 / PCI-6.5UFA1NQ with another model
Hitachi specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Cassette
- Rated cooling capacity (35 Β°C)
- 16.00 kW
- Cooling power input
- 5.03 kW
- Rated heating capacity (7 Β°C)
- 18.00 kW
- Heating power input
- 5.00 kW
- EER, full load (tested)
- 3.29
- COP, full load (tested)
- 3.58
- Rated AEER
- 3.14
- Rated ACOP
- 3.55
- Standby power (PIA)
- 21.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hitachi zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,938 | 1,976 |
| Coldresidential | residential | 3.0 | 2.0 | 925 | 6,265 |
| Mixedcommercial | commercial | β | β | 2,481 | 951 |
| Mixedresidential | residential | 2.5 | 3.0 | 1,480 | 2,208 |
| Hotcommercial | commercial | β | β | 5,588 | 213 |
| Hotresidential | residential | 3.0 | 4.0 | 4,237 | 326 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 4000 W
- c__t1_half_cap_power_rated
- 1540 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1480 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 13500 W
- h__h1_half_cap_heat_cap_rated
- 9000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 4595.592000000001 W
- c__low_temp_half_cap_power_rated
- 1407.56 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 8400 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 17232 W
- c__low_temp_half_cap_cooling_cap_rated
- 9046.8 W
New Zealand E3 registration details
- Registration number
- AAC8083
- GEMS registration id
- 158311
- Status
- approved, available (self-reported)
- Registration expires
- 5 March 2029
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.