c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
2,412 kWh
250 cooling + 2,162 heating
Estimated running cost
$796 / year
$66 / month Β· $7,960 over 10 years
Capacity
5 kW cooling
6 kW heating

12% more electricity than the median of 228 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 15% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 70% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hitachi RAC-XJ50FHAE running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,412$796$7,960
Mixed zone 1,179$389$3,891
Hot zone 1,290$426$4,257

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608
Solar Acdc DGWA1-ACDC-18KR25 kW heating5 kW cooling1,905 kWh/yr3.5$629

Heat pumps similar to the Hitachi RAC-XJ50FHAE

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling1,973 kWh/yr4$651
Hisense HAWG18KR5.3 kW heating5 kW cooling1,993 kWh/yr4$658
Panasonic U-50PZ3R5/S-50PY3E5 kW heating5 kW cooling1,982 kWh/yr2.5$654
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling1,881 kWh/yr5.5$621
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling1,903 kWh/yr5$628
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling1,936 kWh/yr5$639
Toshiba RAV-GP561ATP-A/RAV-GM561UTP-A5.6 kW heating5 kW cooling1,963 kWh/yr4$648
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling1,940 kWh/yr5.5$640

Compare RAC-XJ50FHAE/RAF-XJ50RHAE with another model

Hitachi RAC-XJ50FHAE specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Floor mounted
Rated cooling capacity (35 Β°C)
5.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
6.00 kW
Heating power input
–
EER, full load (tested)
3.85
COP, full load (tested)
3.91
Rated AEER
3.71
Rated ACOP
3.88
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
57 dB(A)
Outdoor sound power
65 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi RAC-XJ50FHAE zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––436681
Coldresidential4.02.02502,162
Mixedcommercial––598348
Mixedresidential3.52.5393786
Hotcommercial––1,51271
Hotresidential4.03.01,177113
Part-load test points (21 values)
c__t1_min_cap_power_rated
300 W
h__h2_ext_cap_power_rated
2000 W
c__t1_half_cap_power_rated
500 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
590 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5350 W
h__h1_half_cap_heat_cap_rated
3000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
223 W
c__t1_min_cap_cooling_cap_rated
1550 W
c__low_temp_half_cap_power_rated
420 W
c__t1_half_cap_cooling_cap_rated
2500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1650 W
c__low_temp_half_cap_cooling_cap_rated
2620 W

New Zealand E3 registration details

Registration number
AAC10277
GEMS registration id
–
Status
approved
Registration expires
2 July 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. Manufacturer: hitachiaircon.com/au. How the derived figures are calculated.