New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Hyundai HYDCTAC71T* Heat Pump
Hyundai HYDCTAC71T* is a 7.1 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9363).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 2,770 kWh
- 367 cooling + 2,403 heating
- Estimated running cost
- $914 / year
- $76 / month Β· $9,141 over 10 years
- Capacity
- 7.1 kW cooling
- 7.5 kW heating
15% less electricity than the median of 80 comparable 7 kW reverse cycle ducted split system registrations (3,279 kWh a year) in the cold zone. Uses less than 89% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 65% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Hyundai HYDCTAC71T* running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,770 | $914 | $9,141 |
| Mixed zone | 1,523 | $503 | $5,026 |
| Hot zone | 1,811 | $598 | $5,976 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling2,674 kWh/yr | 3 | $882 |
Heat pumps similar to the Hyundai HYDCTAC71T*
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAS71C2V1 / FDYA71AV197.5 kW heating7.1 kW cooling2,974 kWh/yr | 3 | $981 | |
| Gree GFH24ACXF-S6DNE3D/O / GFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,127 kWh/yr | 3 | $1,032 | |
| Panasonic U-71PZH3R5 / S-71PE4R8 kW heating7.1 kW cooling3,014 kWh/yr | 3 | $995 | |
| TCL TCD71D1HWH-DVO/TCD71D1HWH-DVI7.5 kW heating7.1 kW cooling2,770 kWh/yr | 3.5 | $914 | |
| Panasonic U-71PZ4R5 / S-71PE4R7.1 kW heating7.1 kW cooling2,870 kWh/yr | 2.5 | $947 | |
| Daikin RZAS71C2V1 / FDYUA71AV197.5 kW heating7.1 kW cooling2,974 kWh/yr | 3 | $981 | |
| Tosot TFH24ACXF-S6DNE3D/O / TFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,127 kWh/yr | 3 | $1,032 | |
| Gree GFH24ACXF-S6DNE3D/O / GFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,133 kWh/yr | 3 | $1,034 |
Compare HYDCTAC71T* with another model
Hyundai HYDCTAC71T* specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 7.10 kW
- Cooling power input
- 1.90 kW
- Rated heating capacity (7 Β°C)
- 7.50 kW
- Heating power input
- 1.73 kW
- EER, full load (tested)
- 3.78
- COP, full load (tested)
- 4.41
- Rated AEER
- 3.69
- Rated ACOP
- 4.28
- Standby power (PIA)
- 7.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 66.3 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hyundai HYDCTAC71T* zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 681 | 792 |
| Coldresidential | residential | 3.5 | 2.5 | 367 | 2,403 |
| Mixedcommercial | commercial | β | β | 916 | 430 |
| Mixedresidential | residential | 3.5 | 2.5 | 580 | 943 |
| Hotcommercial | commercial | β | β | 2,108 | 98 |
| Hotresidential | residential | 4.0 | 3.0 | 1,660 | 151 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 3180 W
- c__t1_half_cap_power_rated
- 720 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 700 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 9000 W
- h__h1_half_cap_heat_cap_rated
- 3570 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 580 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 3500 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 3880 W
Other model numbers on registration AAC9363
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC9363
- GEMS registration id
- 172588
- Status
- approved, available (self-reported)
- Registration expires
- 31 August 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- HYDCTAC71T*
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 10
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.