New Zealand Β· costs in NZD
Reverse cycle fixed air conditioner
Kaden KM13.0 Heat Pump
Kaden KM13.0 is a 13 kW reverse cycle fixed heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC10081).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 5,594 kWh
- 714 cooling + 4,880 heating
- Estimated running cost
- $1,846 / year
- $154 / month Β· $18,460 over 10 years
- Capacity
- 13 kW cooling
- 14 kW heating
1% more electricity than the median of 17 comparable 12.5 kW reverse cycle fixed registrations (5,528 kWh a year) in the cold zone. Uses less than 24% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 34% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Kaden KM13.0 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 5,594 | $1,846 | $18,460 |
| Mixed zone | 2,896 | $956 | $9,557 |
| Hot zone | 3,514 | $1,160 | $11,596 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 13 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38QUM110D8S512.5 kW heating11.6 kW cooling4,367 kWh/yr | 3.5 | $1,441 | |
| Fujitsu AOTH45KBTA513.2 kW heating12.5 kW cooling4,625 kWh/yr | 4 | $1,526 | |
| Bonaire H5M125S1AE12.2 kW heating12.2 kW cooling4,758 kWh/yr | 3.5 | $1,570 | |
| TECO TSOM123HVAG512.6 kW heating12.3 kW cooling4,771 kWh/yr | 3.5 | $1,574 | |
| Midea MULMI0513B14 kW heating13.5 kW cooling4,925 kWh/yr | 4 | $1,625 |
Heat pumps similar to the Kaden KM13.0
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Emerald ACR126U14.5 kW heating12.6 kW cooling6,014 kWh/yr | 3 | $1,985 | |
| Hisense AMW5-125U4RTAG14.2 kW heating12.6 kW cooling5,911 kWh/yr | 3 | $1,951 | |
| Carrier 38QUM135D8S513.5 kW heating13.5 kW cooling5,402 kWh/yr | 3 | $1,783 | |
| Fujitsu AOTG45LBLA613.5 kW heating12.5 kW cooling4,946 kWh/yr | 3.5 | $1,632 | |
| Actron Air MRC-135DS-514 kW heating13.5 kW cooling5,548 kWh/yr | 3.5 | $1,831 | |
| Fujitsu AOTH45KBTA513.2 kW heating12.5 kW cooling4,625 kWh/yr | 4 | $1,526 | |
| Hisense AMW5-125U4RTA13.5 kW heating12.5 kW cooling5,891 kWh/yr | 2.5 | $1,944 | |
| Spt AM140C-514.4 kW heating13.6 kW cooling5,016 kWh/yr | 4 | $1,655 |
Compare KM13.0 with another model
Kaden KM13.0 specifications
- Type
- Reverse cycle
- Configuration
- Fixed
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 13.00 kW
- Cooling power input
- 3.94 kW
- Rated heating capacity (7 Β°C)
- 14.00 kW
- Heating power input
- 3.26 kW
- EER, full load (tested)
- 3.41
- COP, full load (tested)
- 4.29
- Rated AEER
- 3.25
- Rated ACOP
- 4.21
- Standby power (PIA)
- 18.2 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 69.4 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Kaden KM13.0 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,217 | 1,509 |
| Coldresidential | residential | 3.0 | 2.0 | 714 | 4,880 |
| Mixedcommercial | commercial | β | β | 1,687 | 768 |
| Mixedresidential | residential | 3.0 | 2.5 | 1,131 | 1,765 |
| Hotcommercial | commercial | β | β | 4,077 | 178 |
| Hotresidential | residential | 3.5 | 3.5 | 3,240 | 274 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 864 W
- h__h1_min_cap_power_rated
- 703 W
- h__h2_ext_cap_power_rated
- 4981 W
- c__t1_half_cap_power_rated
- 1347 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1362 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3830 W
- h__h2_ext_cap_heat_cap_rated
- 12670 W
- h__h1_half_cap_heat_cap_rated
- 6810 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 635 W
- c__t1_min_cap_cooling_cap_rated
- 4668 W
- c__low_temp_half_cap_power_rated
- 1048.5 W
- c__t1_half_cap_cooling_cap_rated
- 6840 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 4386 W
- c__low_temp_half_cap_cooling_cap_rated
- 6837 W
New Zealand E3 registration details
- Registration number
- AAC10081
- GEMS registration id
- 177487
- Status
- approved, available (self-reported)
- Registration expires
- 21 April 2031
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 20
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com/global. How the derived figures are calculated.