c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
3,376 kWh
402 cooling + 2,974 heating
Estimated running cost
$1,114 / year
$93 / month Β· $11,141 over 10 years
Capacity
7.7 kW cooling
8.2 kW heating

7% less electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 86% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 56% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kaden KSI-7.6 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,376$1,114$11,141
Mixed zone 1,718$567$5,669
Hot zone 2,056$678$6,785

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.7 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling2,745 kWh/yr4$906
Midea UCMI70OB/CASMI70IB7.7 kW heating7 kW cooling2,745 kWh/yr3$906

Heat pumps similar to the Kaden KSI-7.6

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai HONRTX80/HINRTX808.2 kW heating7.7 kW cooling3,376 kWh/yr3.5$1,114
Rinnai HSNRTX808.2 kW heating7.7 kW cooling3,376 kWh/yr3.5$1,114
Midea MFAG80VB-W/MFAG80VB-N8.2 kW heating7.7 kW cooling3,376 kWh/yr3.5$1,114
Midea MFAB-80WD/MFAB-80ND8.2 kW heating7.7 kW cooling3,376 kWh/yr3.5$1,114
Comfee CASG-XG80B/CASN-XG80B8.2 kW heating7.7 kW cooling3,376 kWh/yr3.5$1,114
Carrier 42QHG080N8PB/38QUH080N8PB8.2 kW heating7.7 kW cooling3,376 kWh/yr3.5$1,114
Carrier 38QAF080N8/42QAF080N88.2 kW heating7.7 kW cooling3,376 kWh/yr3.5$1,114
Emerald ACSS769.6 kW heating7.6 kW cooling3,800 kWh/yr5$1,254

Compare KSI-7.6 with another model

Kaden KSI-7.6 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.65 kW
Cooling power input
2.27 kW
Rated heating capacity (7 Β°C)
8.20 kW
Heating power input
2.29 kW
EER, full load (tested)
3.35
COP, full load (tested)
3.61
Rated AEER
3.36
Rated ACOP
3.58
Standby power (PIA)
0.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64.8 dB(A)
Outdoor sound power
69.1 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kaden KSI-7.6 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––685903
Coldresidential3.52.04022,974
Mixedcommercial––966456
Mixedresidential3.52.56401,078
Hotcommercial––2,41288
Hotresidential3.53.01,914142
Part-load test points (23 values)
c__t1_min_cap_power_rated
665 W
h__h1_min_cap_power_rated
465 W
h__h2_ext_cap_power_rated
2992 W
c__t1_half_cap_power_rated
865 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
783 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2402 W
h__h2_ext_cap_heat_cap_rated
7660 W
h__h1_half_cap_heat_cap_rated
3880 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
485 W
c__t1_min_cap_cooling_cap_rated
3030 W
c__low_temp_half_cap_power_rated
680 W
c__t1_half_cap_cooling_cap_rated
3870 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3180 W
c__low_temp_half_cap_cooling_cap_rated
4050 W

New Zealand E3 registration details

Registration number
AAC9139
GEMS registration id
171536
Status
approved, available (self-reported)
Registration expires
29 July 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9