New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Midea MFAB-80WD/MFAB-80ND Heat Pump
Midea MFAB-80WD/MFAB-80ND is a 7.7 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8872).
- Energy rating (cooling)
- 3.5
- Heating: 2
- Annual electricity use
- 3,376 kWh
- 402 cooling + 2,974 heating
- Estimated running cost
- $1,114 / year
- $93 / month Β· $11,141 over 10 years
- Capacity
- 7.7 kW cooling
- 8.2 kW heating
7% less electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 86% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 56% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Midea MFAB-80WD running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,376 | $1,114 | $11,141 |
| Mixed zone | 1,718 | $567 | $5,669 |
| Hot zone | 2,056 | $678 | $6,785 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 7.7 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr | 3 | $853 | |
| Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr | 3 | $860 | |
| Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr | 0.5 | $883 | |
| Midea UCMI70OB/CASMI70IB7.7 kW heating7 kW cooling2,745 kWh/yr | 3 | $906 | |
| Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling2,745 kWh/yr | 4 | $906 |
Heat pumps similar to the Midea MFAB-80WD
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38QRF080N8/42QRF080N88.2 kW heating7.7 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Kaden KSI-7.68.2 kW heating7.7 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Carrier 42QHG080N8PB/38QUH080N8PB8.2 kW heating7.7 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Rinnai HSNRTX808.2 kW heating7.7 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Rinnai HONRTX80/HINRTX808.2 kW heating7.7 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Comfee CASG-XG80B/CASN-XG80B8.2 kW heating7.7 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Emerald ACSS769.6 kW heating7.6 kW cooling3,800 kWh/yr | 5 | $1,254 | |
| Kaden KSI288.5 kW heating7.6 kW cooling3,493 kWh/yr | 3.5 | $1,153 |
Compare MFAB-80WD/MFAB-80ND with another model
Midea MFAB-80WD specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 7.65 kW
- Cooling power input
- 2.27 kW
- Rated heating capacity (7 Β°C)
- 8.20 kW
- Heating power input
- 2.29 kW
- EER, full load (tested)
- 3.35
- COP, full load (tested)
- 3.61
- Rated AEER
- 3.36
- Rated ACOP
- 3.58
- Standby power (PIA)
- 0.7 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 64.8 dB(A)
- Outdoor sound power
- 69.1 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea MFAB-80WD zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 685 | 903 |
| Coldresidential | residential | 3.5 | 2.0 | 402 | 2,974 |
| Mixedcommercial | commercial | β | β | 966 | 456 |
| Mixedresidential | residential | 3.5 | 2.5 | 640 | 1,078 |
| Hotcommercial | commercial | β | β | 2,412 | 88 |
| Hotresidential | residential | 3.5 | 3.0 | 1,914 | 142 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 665 W
- h__h1_min_cap_power_rated
- 465 W
- h__h2_ext_cap_power_rated
- 2992 W
- c__t1_half_cap_power_rated
- 865 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 783 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2402 W
- h__h2_ext_cap_heat_cap_rated
- 7660 W
- h__h1_half_cap_heat_cap_rated
- 3880 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 485 W
- c__t1_min_cap_cooling_cap_rated
- 3030 W
- c__low_temp_half_cap_power_rated
- 680 W
- c__t1_half_cap_cooling_cap_rated
- 3870 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3180 W
- c__low_temp_half_cap_cooling_cap_rated
- 4050 W
New Zealand E3 registration details
- Registration number
- AAC8872
- GEMS registration id
- 169424
- Status
- approved, available (self-reported)
- Registration expires
- 21 May 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.