c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
3,440 kWh
408 cooling + 3,032 heating
Estimated running cost
$1,135 / year
$95 / month Β· $11,352 over 10 years
Capacity
8.2 kW cooling
8.8 kW heating

7% less electricity than the median of 9 comparable 8 kW reverse cycle multi-split / vrf registrations (3,713 kWh a year) in the cold zone. Uses less than 56% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 54% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kinghome KWHD(28)NK6PO running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,440$1,135$11,352
Mixed zone 1,721$568$5,679
Hot zone 1,982$654$6,541

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Kinghome KWHD(24)NK6PO8.3 kW heating7.3 kW cooling3,237 kWh/yr3$1,068
Toshiba MCY-MHP0305HT9 kW heating8 kW cooling3,321 kWh/yr3$1,096
Carrier 38VS00318SHCSS9 kW heating8 kW cooling3,321 kWh/yr3$1,096

Heat pumps similar to the Kinghome KWHD(28)NK6PO

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG 4MXM80MA09.2 kW heating8.2 kW cooling3,713 kWh/yr3.5$1,225
Mdv MV8M-80WV2N89 kW heating8 kW cooling3,821 kWh/yr2$1,261
Midea MV8M-80WV2N89 kW heating8 kW cooling3,821 kWh/yr2$1,261
Actron Air MMV-080CS9 kW heating8 kW cooling3,821 kWh/yr2$1,261
Carrier 38VS00318SHCSS9 kW heating8 kW cooling3,321 kWh/yr3$1,096
Toshiba MCY-MHP0305HT9 kW heating8 kW cooling3,321 kWh/yr3$1,096
Mitsubishi Heavy Industries SCM80ZS-W9.3 kW heating8 kW cooling3,386 kWh/yr3.5$1,117
LG UHXM90MA110.1 kW heating8.8 kW cooling4,811 kWh/yr3$1,588

Compare KWHD(28)NK6PO with another model

Kinghome KWHD(28)NK6PO specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
Floor mounted
Rated cooling capacity (35 Β°C)
8.20 kW
Cooling power input
1.88 kW
Rated heating capacity (7 Β°C)
8.80 kW
Heating power input
2.12 kW
EER, full load (tested)
4.38
COP, full load (tested)
4.35
Rated AEER
4.28
Rated ACOP
4.09
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64.6 dB(A)
Outdoor sound power
68.8 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kinghome KWHD(28)NK6PO zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––870947
Coldresidential3.52.04083,032
Mixedcommercial––1,093483
Mixedresidential3.53.06341,087
Hotcommercial––2,420110
Hotresidential4.03.51,814168
Part-load test points (16 values)
h__h2_ext_cap_power_rated
2100 W
c__t1_half_cap_power_rated
680 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
780 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
6900 W
h__h1_half_cap_heat_cap_rated
4400 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
4100 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC10358
GEMS registration id
181246
Status
approved, available (self-reported)
Registration expires
3 August 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.