New Zealand Β· costs in NZD

Reverse cycle window / wall air conditioner
Kogan KASVWAC30Y* Heat Pump
Kogan KASVWAC30Y* is a 3.1 kW reverse cycle window / wall heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8146).
- Energy rating (cooling)
- 2
- Heating: 1
- Annual electricity use
- 1,767 kWh
- 217 cooling + 1,550 heating
- Estimated running cost
- $583 / year
- $49 / month Β· $5,831 over 10 years
- Capacity
- 3.1 kW cooling
- 3.2 kW heating
24% less electricity than the median of 15 comparable 3.5 kW reverse cycle window / wall registrations (2,316 kWh a year) in the cold zone. Uses less than 93% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 78% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Kogan KASVWAC30Y* running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,767 | $583 | $5,831 |
| Mixed zone | 898 | $296 | $2,963 |
| Hot zone | 1,078 | $356 | $3,557 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 3.1 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MWFF28H2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Westinghouse WWH28HWC2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Midea MWFF26H2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Kaden KW092.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 | |
| TECO TWW27HFWDG2.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 |
Heat pumps similar to the Kogan KASVWAC30Y*
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| TECO TVS32HVUVBH3.2 kW heating3.1 kW cooling1,838 kWh/yr | 2 | $607 | |
| TECO TVS32HVWBH3.2 kW heating3.1 kW cooling1,838 kWh/yr | 2 | $607 | |
| Kelvinator KWH27HRF2.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 | |
| Midea MWFF28H2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Gree GJH09AK-K6NRND6A2.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 | |
| Westinghouse WWH28HWC2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Midea MWFF26H2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Kaden KW092.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 |
Compare KASVWAC30Y* with another model
Kogan KASVWAC30Y* specifications
- Type
- Reverse cycle
- Configuration
- Window / wall
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 3.08 kW
- Cooling power input
- 1.00 kW
- Rated heating capacity (7 Β°C)
- 3.22 kW
- Heating power input
- 0.95 kW
- EER, full load (tested)
- 3.09
- COP, full load (tested)
- 3.34
- Rated AEER
- 3.07
- Rated ACOP
- 3.38
- Standby power (PIA)
- 1.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 59 dB(A)
- Outdoor sound power
- 65 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Kogan KASVWAC30Y* zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 464 | 448 |
| Coldresidential | residential | 2.0 | 1.0 | 217 | 1,550 |
| Mixedcommercial | commercial | β | β | 583 | 225 |
| Mixedresidential | residential | 2.0 | 1.5 | 335 | 563 |
| Hotcommercial | commercial | β | β | 1,362 | 42 |
| Hotresidential | residential | 2.0 | 2.5 | 1,010 | 68 |
Part-load test points (22 values)
- h__h1_min_cap_power_rated
- 250 W
- c__t1_half_cap_power_rated
- 460 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 430 W
- h__h1_have_min_cap_results
- Yes
- h__h2_full_cap_power_rated
- 980 W
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 1150 W
- h__h1_half_cap_heat_cap_rated
- 1680 W
- h__h2_full_cap_heat_cap_rated
- 2200 W
- h__h2_is_capable_extended_load
- No
- c__low_temp_min_cap_power_rated
- 210 W
- c__low_temp_full_cap_power_rated
- 914 W
- c__low_temp_half_cap_power_rated
- 420.44 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 1630 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_min_cap_cooling_cap_rated
- 1070 W
- c__low_temp_full_cap_cooling_cap_rated
- 3317.16 W
- c__low_temp_half_cap_cooling_cap_rated
- 1755.51 W
Other model numbers on registration AAC8146
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC8146
- GEMS registration id
- 160276
- Status
- approved, available (self-reported)
- Registration expires
- 26 March 2029
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- KASVWAC30Y*
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 5
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.