c/kWh
Energy rating (cooling)
6.5
Heating: 3
Annual electricity use
1,015 kWh
89 cooling + 926 heating
Estimated running cost
$335 / year
$28 / month Β· $3,350 over 10 years
Capacity
2.6 kW cooling
3.2 kW heating

5% less electricity than the median of 177 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 65% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 89% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea MFAB-26WD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,015$335$3,350
Mixed zone 492$162$1,624
Hot zone 459$151$1,515

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr7$265

Heat pumps similar to the Midea MFAB-26WD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai HONRPX25/HINRPX25M3.3 kW heating2.6 kW cooling1,009 kWh/yr6.5$333
LG WS09TWU / WS09TWN3.2 kW heating2.6 kW cooling1,162 kWh/yr4$383
Kaden KSI092.7 kW heating2.6 kW cooling923 kWh/yr5$305
Kaden KS092.8 kW heating2.6 kW cooling1,018 kWh/yr4.5$336
Kogan KASSSAC26TC3.3 kW heating2.6 kW cooling1,122 kWh/yr5$370
TECO TWS-TSO26H3DVKT3.3 kW heating2.6 kW cooling1,131 kWh/yr4.5$373
Kogan KASSSAC26TB3.3 kW heating2.6 kW cooling1,122 kWh/yr5$370
TCL TAC-10CHSD/XA72IG3.3 kW heating2.6 kW cooling1,122 kWh/yr5$370

Compare MFAB-26WD/MFAB-26ND with another model

Midea MFAB-26WD specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.60 kW
Cooling power input
0.51 kW
Rated heating capacity (7 Β°C)
3.20 kW
Heating power input
0.69 kW
EER, full load (tested)
5.05
COP, full load (tested)
4.61
Rated AEER
5.05
Rated ACOP
4.59
Standby power (PIA)
0.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
55.5 dB(A)
Outdoor sound power
62.1 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea MFAB-26WD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––99295
Coldresidential6.53.089926
Mixedcommercial––180155
Mixedresidential6.03.0142350
Hotcommercial––44732
Hotresidential6.54.040950
Part-load test points (23 values)
c__t1_min_cap_power_rated
175 W
h__h1_min_cap_power_rated
180 W
h__h2_ext_cap_power_rated
1070 W
c__t1_half_cap_power_rated
238 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
279 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1025 W
h__h2_ext_cap_heat_cap_rated
3435 W
h__h1_half_cap_heat_cap_rated
1628 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
110 W
c__t1_min_cap_cooling_cap_rated
970 W
c__low_temp_half_cap_power_rated
145 W
c__t1_half_cap_cooling_cap_rated
1360 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
980 W
c__low_temp_half_cap_cooling_cap_rated
1300 W

New Zealand E3 registration details

Registration number
AAC8943
GEMS registration id
169523
Status
approved, available (self-reported)
Registration expires
1 June 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.