New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Midea MFEF80VA-W/MFEF80VA-N Heat Pump
Midea MFEF80VA-W/MFEF80VA-N is a 8 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8968).
- Energy rating (cooling)
- 4
- Heating: 2
- Annual electricity use
- 3,555 kWh
- 402 cooling + 3,153 heating
- Estimated running cost
- $1,173 / year
- $98 / month Β· $11,732 over 10 years
- Capacity
- 8 kW cooling
- 8.7 kW heating
2% less electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 60% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 52% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Midea MFEF80VA-W running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,555 | $1,173 | $11,732 |
| Mixed zone | 1,794 | $592 | $5,920 |
| Hot zone | 2,069 | $683 | $6,828 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 8 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,650 kWh/yr | 3 | $875 | |
| Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,665 kWh/yr | 3 | $879 | |
| Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr | 0.5 | $883 | |
| Midea UCMI70OB/CASMI70IB7.7 kW heating7 kW cooling2,745 kWh/yr | 3 | $906 | |
| Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling2,745 kWh/yr | 4 | $906 |
Heat pumps similar to the Midea MFEF80VA-W
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air HRC-080DS / HRE-080DS8.7 kW heating8 kW cooling3,555 kWh/yr | 4 | $1,173 | |
| Rinnai HONRPX80/HINRPX80M8.7 kW heating8 kW cooling3,555 kWh/yr | 4 | $1,173 | |
| Westinghouse WSD79HWC-E / WSD79HWC-I8.7 kW heating8 kW cooling3,560 kWh/yr | 3.5 | $1,175 | |
| Carrier Carrier Ambi8.7 kW heating8 kW cooling3,555 kWh/yr | 4 | $1,173 | |
| Kogan KASSSAC80HE8.2 kW heating8 kW cooling3,283 kWh/yr | 4.5 | $1,083 | |
| Kogan KASSSAC80HD8.2 kW heating8 kW cooling3,283 kWh/yr | 4.5 | $1,083 | |
| Comfee CASG-XG80/CASN-XG808.2 kW heating7.9 kW cooling3,328 kWh/yr | 3.5 | $1,098 | |
| Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling3,371 kWh/yr | 3.5 | $1,112 |
Compare MFEF80VA-W/MFEF80VA-N with another model
Midea MFEF80VA-W specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 7.95 kW
- Cooling power input
- 2.33 kW
- Rated heating capacity (7 Β°C)
- 8.70 kW
- Heating power input
- 2.40 kW
- EER, full load (tested)
- 3.36
- COP, full load (tested)
- 3.59
- Rated AEER
- 3.42
- Rated ACOP
- 3.63
- Standby power (PIA)
- 0.7 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 67.3 dB(A)
- Outdoor sound power
- 69.1 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea MFEF80VA-W zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 673 | 967 |
| Coldresidential | residential | 4.0 | 2.0 | 402 | 3,153 |
| Mixedcommercial | commercial | β | β | 962 | 491 |
| Mixedresidential | residential | 3.5 | 2.5 | 645 | 1,149 |
| Hotcommercial | commercial | β | β | 2,372 | 96 |
| Hotresidential | residential | 3.5 | 3.0 | 1,916 | 153 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 625 W
- h__h1_min_cap_power_rated
- 534 W
- h__h2_ext_cap_power_rated
- 3295 W
- c__t1_half_cap_power_rated
- 825 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 830 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2700 W
- h__h2_ext_cap_heat_cap_rated
- 8305 W
- h__h1_half_cap_heat_cap_rated
- 4085 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 465 W
- c__t1_min_cap_cooling_cap_rated
- 2700 W
- c__low_temp_half_cap_power_rated
- 620 W
- c__t1_half_cap_cooling_cap_rated
- 3700 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3080 W
- c__low_temp_half_cap_cooling_cap_rated
- 3890 W
New Zealand E3 registration details
- Registration number
- AAC8968
- GEMS registration id
- 169577
- Status
- approved, available (self-reported)
- Registration expires
- 3 June 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.