c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
3,555 kWh
402 cooling + 3,153 heating
Estimated running cost
$1,173 / year
$98 / month Β· $11,732 over 10 years
Capacity
8 kW cooling
8.7 kW heating

2% less electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 60% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 52% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea MFEZ80VA-W running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,555$1,173$11,732
Mixed zone 1,794$592$5,920
Hot zone 2,069$683$6,828

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,650 kWh/yr3$875
Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,665 kWh/yr3$879
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Midea UCMI70OB/CASMI70IB7.7 kW heating7 kW cooling2,745 kWh/yr3$906
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling2,745 kWh/yr4$906

Heat pumps similar to the Midea MFEZ80VA-W

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air HRC-080DS / HRE-080DS8.7 kW heating8 kW cooling3,555 kWh/yr4$1,173
Rinnai HONRPX80/HINRPX80M8.7 kW heating8 kW cooling3,555 kWh/yr4$1,173
Westinghouse WSD79HWC-E / WSD79HWC-I8.7 kW heating8 kW cooling3,560 kWh/yr3.5$1,175
Carrier Carrier Ambi8.7 kW heating8 kW cooling3,555 kWh/yr4$1,173
Kogan KASSSAC80HE8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Kogan KASSSAC80HD8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Comfee CASG-XG80/CASN-XG808.2 kW heating7.9 kW cooling3,328 kWh/yr3.5$1,098
Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112

Compare MFEZ80VA-W/MFEZ80VA-N with another model

Midea MFEZ80VA-W specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.95 kW
Cooling power input
2.33 kW
Rated heating capacity (7 Β°C)
8.70 kW
Heating power input
2.40 kW
EER, full load (tested)
3.36
COP, full load (tested)
3.59
Rated AEER
3.42
Rated ACOP
3.63
Standby power (PIA)
0.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
67.3 dB(A)
Outdoor sound power
69.1 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea MFEZ80VA-W zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––673967
Coldresidential4.02.04023,153
Mixedcommercial––962491
Mixedresidential3.52.56451,149
Hotcommercial––2,37296
Hotresidential3.53.01,916153
Part-load test points (23 values)
c__t1_min_cap_power_rated
625 W
h__h1_min_cap_power_rated
534 W
h__h2_ext_cap_power_rated
3295 W
c__t1_half_cap_power_rated
825 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
830 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2700 W
h__h2_ext_cap_heat_cap_rated
8305 W
h__h1_half_cap_heat_cap_rated
4085 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
465 W
c__t1_min_cap_cooling_cap_rated
2700 W
c__low_temp_half_cap_power_rated
620 W
c__t1_half_cap_cooling_cap_rated
3700 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3080 W
c__low_temp_half_cap_cooling_cap_rated
3890 W

New Zealand E3 registration details

Registration number
AAC8959
GEMS registration id
169580
Status
approved, available (self-reported)
Registration expires
3 June 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.