New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, under ceiling
Mitsubishi Electric PUZ-ZM140YKA-A/PCA-M140KA Heat Pump
Mitsubishi Electric PUZ-ZM140YKA-A/PCA-M140KA is a 13.5 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7886).
- Energy rating (cooling)
- 2
- Heating: 1.5
- Annual electricity use
- 7,449 kWh
- 911 cooling + 6,538 heating
- Estimated running cost
- $2,458 / year
- $205 / month Β· $24,582 over 10 years
- Capacity
- 13.5 kW cooling
- 16 kW heating
12% more electricity than the median of 66 comparable 14 kW reverse cycle split system registrations (6,658 kWh a year) in the cold zone. Uses less than 17% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 22% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Mitsubishi Electric PUZ-ZM140YKA-A running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 7,449 | $2,458 | $24,582 |
| Mixed zone | 3,765 | $1,242 | $12,425 |
| Hot zone | 4,318 | $1,425 | $14,249 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 13.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr | 3 | $1,528 | |
| Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr | 3 | $1,528 | |
| Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr | 4 | $1,654 | |
| Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr | 4 | $1,654 | |
| Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr | 4 | $1,657 |
Heat pumps similar to the Mitsubishi Electric PUZ-ZM140YKA-A
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-140PZ4R5 / S-1014PT3E14 kW heating13.6 kW cooling5,971 kWh/yr | 2.5 | $1,970 | |
| Panasonic U-140PZ4R8 / S-1014PT3E14 kW heating13.6 kW cooling5,971 kWh/yr | 2.5 | $1,970 | |
| Mitsubishi Heavy Industries FDC(A)140VSX-W / FDE140VH16 kW heating14 kW cooling6,552 kWh/yr | 2.5 | $2,162 | |
| Mitsubishi Heavy Industries FDCA140VSX-W / FDE140VH16 kW heating14 kW cooling6,552 kWh/yr | 2.5 | $2,162 | |
| Fujitsu AOTH54KBTA/ABTH54KRTA15.5 kW heating13 kW cooling6,247 kWh/yr | 3 | $2,062 | |
| Hisense AUW-140U4RN1/ AUC-140U4RKC115 kW heating13.5 kW cooling8,256 kWh/yr | 2.5 | $2,724 |
Other Mitsubishi Electric models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Electric PUZ-ZM140VKA2-A/PCA-M140KA216 kW heating13.5 kW cooling6,597 kWh/yr | 2 | $2,177 | |
| Mitsubishi Electric PUZ-ZM140VKA-A/PCA-M140KA Series16 kW heating13.5 kW cooling6,597 kWh/yr | 2 | $2,177 |
Compare PUZ-ZM140YKA-A/PCA-M140KA with another model
Mitsubishi Electric PUZ-ZM140YKA-A specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Under ceiling
- Rated cooling capacity (35 Β°C)
- 13.50 kW
- Cooling power input
- 4.15 kW
- Rated heating capacity (7 Β°C)
- 16.00 kW
- Heating power input
- 4.72 kW
- EER, full load (tested)
- 3.65
- COP, full load (tested)
- 3.77
- Rated AEER
- 3.17
- Rated ACOP
- 3.31
- Standby power (PIA)
- 33.6 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 1600 Γ 230 Γ 680 mm
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mitsubishi Electric PUZ-ZM140YKA-A zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,883 | 2,039 |
| Coldresidential | residential | 2.0 | 1.5 | 911 | 6,538 |
| Mixedcommercial | commercial | β | β | 2,365 | 1,046 |
| Mixedresidential | residential | 2.0 | 2.0 | 1,408 | 2,357 |
| Hotcommercial | commercial | β | β | 5,211 | 255 |
| Hotresidential | residential | 2.5 | 2.5 | 3,935 | 383 |
Part-load test points (16 values)
- h__h2_ext_cap_power_rated
- 5840 W
- c__t1_half_cap_power_rated
- 1430 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1630 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 13200 W
- h__h1_half_cap_heat_cap_rated
- 8000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 6750 W
- c__low_temp_have_half_cap_results
- No
Other model numbers on registration AAC7886
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC7886
- GEMS registration id
- 157865
- Status
- approved, available (self-reported)
- Registration expires
- 14 November 2028
- Registered for sale in
- Australia, New Zealand
- Family
- PUZ-ZM140YKA-A/PCA-M140KA Series
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: MitsubishiElectric.com.au. How the derived figures are calculated.