c/kWh
Energy rating (cooling)
2
Heating: 1.5
Annual electricity use
7,449 kWh
911 cooling + 6,538 heating
Estimated running cost
$2,458 / year
$205 / month Β· $24,582 over 10 years
Capacity
13.5 kW cooling
16 kW heating

12% more electricity than the median of 66 comparable 14 kW reverse cycle split system registrations (6,658 kWh a year) in the cold zone. Uses less than 17% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 22% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mitsubishi Electric PUZ-ZM140YKA-A running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,449$2,458$24,582
Mixed zone 3,765$1,242$12,425
Hot zone 4,318$1,425$14,249

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 13.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657

Heat pumps similar to the Mitsubishi Electric PUZ-ZM140YKA-A

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-140PZ4R5 / S-1014PT3E14 kW heating13.6 kW cooling5,971 kWh/yr2.5$1,970
Panasonic U-140PZ4R8 / S-1014PT3E14 kW heating13.6 kW cooling5,971 kWh/yr2.5$1,970
Mitsubishi Heavy Industries FDC(A)140VSX-W / FDE140VH16 kW heating14 kW cooling6,552 kWh/yr2.5$2,162
Mitsubishi Heavy Industries FDCA140VSX-W / FDE140VH16 kW heating14 kW cooling6,552 kWh/yr2.5$2,162
Fujitsu AOTH54KBTA/ABTH54KRTA15.5 kW heating13 kW cooling6,247 kWh/yr3$2,062
Hisense AUW-140U4RN1/ AUC-140U4RKC115 kW heating13.5 kW cooling8,256 kWh/yr2.5$2,724

Other Mitsubishi Electric models of similar capacity

ModelStarsEst. cost / yrCompare
Mitsubishi Electric PUZ-ZM140VKA2-A/PCA-M140KA216 kW heating13.5 kW cooling6,597 kWh/yr2$2,177
Mitsubishi Electric PUZ-ZM140VKA-A/PCA-M140KA Series16 kW heating13.5 kW cooling6,597 kWh/yr2$2,177

Compare PUZ-ZM140YKA-A/PCA-M140KA2 with another model

Mitsubishi Electric PUZ-ZM140YKA-A specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Under ceiling
Rated cooling capacity (35 Β°C)
13.50 kW
Cooling power input
4.15 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
4.72 kW
EER, full load (tested)
3.65
COP, full load (tested)
3.77
Rated AEER
3.17
Rated ACOP
3.31
Standby power (PIA)
33.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1600 Γ— 230 Γ— 680 mm
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Electric PUZ-ZM140YKA-A zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,8832,039
Coldresidential2.01.59116,538
Mixedcommercial––2,3651,046
Mixedresidential2.02.01,4082,357
Hotcommercial––5,211255
Hotresidential2.52.53,935383
Part-load test points (16 values)
h__h2_ext_cap_power_rated
5840 W
c__t1_half_cap_power_rated
1430 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1630 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
13200 W
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
6750 W
c__low_temp_have_half_cap_results
No

Other model numbers on registration AAC7886

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7886
GEMS registration id
157865
Status
approved, available (self-reported)
Registration expires
14 November 2028
Registered for sale in
Australia, New Zealand
Family
PUZ-ZM140YKA-A/PCA-M140KA Series
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: MitsubishiElectric.com.au. How the derived figures are calculated.